1.0 General Description1.1 Product DescriptionThis Specification defines the input, output, performance characteristics environment, noise and safety requirements for a power supply1.2 Parameter SpecificationUnless specification otherwise, all parameters must be met over the limit of temperature, load, and input voltage.2.0 Electrical Requirements2.1 Input requirements2.1.1 Input VoltagesNormal voltage : 100 to 240Vrms
Voltage range :
90 to 264Vrms2.1.2 Inrush CurrentThe inrush current should cause no damage to the power supply which is testing at any AC input voltage as specified in 2-1-1. And inrush current at 115VAC must be limited 30A max. at cold start,for 240VAC it must be limited to 50A Max. at cold start.2.1.3 Input FuseThe live line side of the input shall not blow up.2.1.4 Input Currentless than
1.3Arms at 90 to 264Vac input2.1.5 Frequency60 ± 3Hz / 50 ± 3Hz2.1.6 EfficiencyWhen 230Vac input voltage, the efficiency shall be 78% or better under maximum load.2.1.7 Primary Over Current ProtectionAn adequate internal fuse on the AC input line shall be provided.2.1.8 DPMS ModeInput 230vac 50Hz : Under 1 W(NO-load).
Input 230vac 50Hz at LOAD 250mW : Input power Consumption under 1W2.1.9 Configuration3 Conductors (Live, neutral, F.G)2.1.10 Earth Leakage Current.0.75mA Max (250V, 50Hz)2.1.11 Hi-pot tests (Dielectric withstand voltage)1.8KV / 1sec (AC) at 10mA ( Primary to Secondary )2.1.12 Insulation ResistanceInsulation resistance shall be more than 25M at 500Vdc between Primary Live,neutral line and secondary. 1.0 General Description1.1 Product DescriptionThis Specification defines the input, output, performance characteristics environment, noise and safety requirements for a power supply1.2 Parameter SpecificationUnless specification otherwise, all parameters must be met over the limit of temperature, load, and input voltage.2.0 Electrical Requirements2.1 Input requirements2.1.1 Input VoltagesNormal voltage : 100 to 240Vrms
Voltage range :
90 to 264Vrms2.1.2 Inrush CurrentThe inrush current should cause no damage to the power supply which is testing at any AC input voltage as specified in 2-1-1. And inrush current at 115VAC must be limited 30A max. at cold start,for 240VAC it must be limited to 50A Max. at cold start.2.1.3 Input FuseThe live line side of the input shall not blow up.2.1.4 Input Currentless than
1.3Arms at 90 to 264Vac input2.1.5 Frequency60 ± 3Hz / 50 ± 3Hz2.1.6 EfficiencyWhen 230Vac input voltage, the efficiency shall be 78% or better under maximum load.2.1.7 Primary Over Current ProtectionAn adequate internal fuse on the AC input line shall be provided.2.1.8 DPMS ModeInput 230vac 50Hz : Under 1 W(NO-load).