NLP25 Series WebSheet
- Total Max Power: 25 W
- Total Max Current: 5 A
- Input Voltage: 85 V to 264 V
- Output Voltage: -12 V to 48 V
- Outputs: Single, Dual, Triple
- Size (L x W x H): 4.000" x 2.010" x 0.900"
- Warranty: 2 years
- Operating Temperature: 0 to +70 C
OUTPUT SPECIFICATIONS
Total regulation Main output ±2.0%
(Line and load) Auxiliary outputs ±5.0%
Overshoot/undershoot At turn-on 2.0%
Transient response Main output ±5.0% max. dev.,
50% to 100% 1ms recovery
full load step to 1.0%
Temperature coefficient ±0.02%/°C
Overvoltage protection Main output See table
Short circuit protection Continuous with
autorestart
Minimum output current See table
INPUT SPECIFICATIONS
Input voltage range Universal input 90 to 264VAC
127 to 375VDC
Input frequency range 47Hz to 440Hz
Input current 90VAC 0.75A rms max.
230VAC 0.35A rms max.
Safety ground 120VAC, 60Hz 0.2mA
leakage current 230VAC, 50Hz 0.4mA
EMC CHARACTERISTICS
Radiated emissions EN55022/11, FCC part 15 Level A
Conducted emissions EN55022/11, FCC part 15 Level B
Electrostatic discharge EN61000-4-2 Level 2
Electrical fast EN61000-4-4 Level 3
transients/bursts
Surge susceptibility EN61000-4-5 Level 3
RF field susceptibility EN61000-4-3 Level 3
RF conducted EN61000-4-6 Level 3
disturbance
GENERAL SPECIFICATIONS
Hold-up time 110VAC @ full load 5ms typ.
Efficiency 110VAC @ full load 70% typ.
Isolation voltage Input/output 3000VAC
Input/chassis 1500VAC
Switching frequency Fixed 60kHz, ±10kHz
Approvals and EN60950, IEC950
standards VDE0805, UL1950
(See Notes 4, 8) CSA C22.2 No. 950
Weight 115g (4oz)
MTBF MIL-HDBK-217F 150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient, FL 0°C to +50°C
(See Notes 7, 8) Non-operating -40°C to +85°C
0°C to 50°C, ambient, Full load
convection cooled
Peak See Note 1
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 6) 5Hz to 500Hz 2.4G rms peak
Shock MIL-STD-810E 516.4 Part IV