| Specifications | |||||
Input | |||||
| Input Voltage | 80-264 VAC (120-370 VDC), derate output power <90 VAC (See datasheet) | ||||
| Input Frequency | 47-400 Hz (See datasheet) | ||||
| Input Current | 2.5 A typical at 115 VAC, full load, 1.3 A typical at 230 VAC, full load | ||||
| Inrush Current | 40 A max at 230 VAC, cold start (25 ºC) | ||||
| Power Factor | EN61000-3-2, class A | ||||
| Earth Leakage Current | 265 μA at 264 VAC/60 Hz max. 0.5/1.1 mA 115/230 VAC at 400 Hz typ. | ||||
| Input Protection | Internal T5.0 A/250 V fuse in line and neutral | ||||
Output | |||||
| Output Voltage | 12-48 VDC (See datasheet) | ||||
| Output Voltage Trim | ±5%, fan output will track by same percentage | ||||
| Initial Set Accuracy | ±1% V1, ±5% V2, ±3% V3 | ||||
| Minimum Load | 0.1 A required for V2 regulation | ||||
| Start Up Delay | 1.5 s max | ||||
| Start Up Rise Time | 10 ms max | ||||
| Hold Up Time | 16 ms min at 115 VAC | ||||
| Drift | ±0.2% after 20 min warm up | ||||
| Line Regulation | ±0.5% max | ||||
| Load Regulation | ±1% V1, ±5% V2 & V3 max | ||||
| Over/Undershoot | 5% typical | ||||
| Transient Response | 4% max. deviation, recovery to within 1% in 500 μs for a 50-75-50% load change | ||||
| Ripple & Noise | 1% pk-pk V1, others 2%, 20 MHz bandwidth | ||||
| Overvoltage Protection | 115-140% Vnom, recycle input to reset | ||||
| Overload Protection | 110-150% V1 only | ||||
| Short Circuit Protection | Continuous trip and restart (Hiccup mode) | ||||
| Temperature Coefficient | 0.05%/°C | ||||
| Remote Sense | Compensates for 0.5 V total voltage drop | ||||
| Remote On/Off (Inhibit/Enable Option -A) | Uncommitted isolated optocoupler diode, powered diode inhibits V1 & V2 | ||||
General | |||||
| Efficiency | 88% typical | ||||
| Isolation | 4000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground | ||||
| Switching Frequency | 70 kHz typical | ||||
| Signals (Option -A) | Power OK - open collector, Remote On/Off, 5 V Standby | ||||
| MTBF | 220 kHrs to MIL-HDBK-217F at 25 ºC, GB | ||||
| Power Density | 7.2 W/cubic inch | ||||
Environmental | |||||
| Operating Temperature | 0 °C to +70 °C derate linearly from +50 °C at 2.5%/°C to 50% load at +70 °C when convection-cooled and from +60 °C at 2.5%/°C to 75% load at +70 °C when forced-cooled. See longform datasheet for derating & thermal considerations. | ||||
| Cooling | Convection & fan cooled ratings (see datasheet) | ||||
| Operating Humidity | 95% RH, non-condensing | ||||
| Storage Temperature | -40 °C to +85 °C | ||||
| Operating Altitude | 3000 m | ||||
| Shock | 30 g pk, half sine, 6 axes | ||||
| Vibration | 2 g rms, 5 Hz to 500 Hz, 3 axes | ||||
EMC and Safety | |||||
| Low Voltage PSU EMC | EN61204-3, high severity level as below | ||||
| Emissions | EN55022 level B conducted, EN55022 level A radiated | ||||
| Harmonic Currents | EN61000-3-2, class A | ||||
| Voltage Flicker | EN61000-3-3 | ||||
| Radiated Immunity | EN61000-4-3, level 3 Perf Criteria A | ||||
| EFT/Burst | EN61000-4-4, level 3 Perf Criteria A | ||||
| Surge | EN61000-4-5, installation class 3, Perf Criteria A | ||||
| Conducted Immunity | EN61000-4-6, level 3 Perf Criteria A | ||||
| Dips & Interruptions | EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B. EN60601-1, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A (with 50% load), A, B | ||||
| Safety Approvals | See datasheet | ||||
| Equipment Protection Class | Class I and Class II | ||||
| Model Number | Input | Output | Power | |
| ECM140 COVER KIT | Stock Check | ||||
| ECM140US28 | |||||
| ECM140US12 | 80-264 VAC (120-370 VDC) | 12 V/11.7 A | 148 W | Stock Check | |
| ECM140US15 | 80-264 VAC (120-370 VDC) | 15 V/9.3 A | 148 W | Stock Check | |
| ECM140US18 | 80-264 VAC (120-370 VDC) | 18 V/7.7 A | 148 W | Stock Check | |
| ECM140US24 | 80-264 VAC (120-370 VDC) | 24 V/5.8 A | 148 W | Stock Check | |
| ECM140US48 | 80-264 VAC (120-370 VDC) | 48 V/2.9 A | 148 W | Stock |