Specifications | |||||
Input | |||||
Input Voltage | 90-264 VAC (120-370 VDC) | ||||
Input Frequency | 47-63 Hz | ||||
Input Current | 1.6 A at 115 VAC, 1.0 A at 230 VAC | ||||
Inrush Current | <15 A at 115 VAC, cold start at 25 °C <30 A at 230 VAC, cold start at 25 °C | ||||
Earth Leakage Current | <0.30 mA at 115 VAC, <0.75 mA at 240 VAC | ||||
Power Factor | EN61000-3-2, Class A | ||||
Input Protection | T2 A/250 VAC internal fuse in line | ||||
Output | |||||
Output Voltage | See table on datasheet | ||||
Output Voltage Adjustment | ±10% on V1 only (see note 4 on datasheet) | ||||
Minimum Load | 10% required on V1 & V2 of multi-output models to maintain regulation, unit will start up with no load | ||||
Start Up Delay | 2 s typical | ||||
Initial Set Accuracy | Single output models: ±1% Multi-output models: ±5% | ||||
Hold Up Time | 12 ms min at 110 VAC, 100% load | ||||
Line Regulation | 1% from low line to high line | ||||
Load Regulation | 7% max all models 3% typical, 10% with no load on V1 - see table on datasheet | ||||
Transient Response | 4% max deviation, recovery to within 1% in 4 ms for a 50% load change | ||||
Ripple & Noise | 1% pk-pk typical, 20 MHz bandwidth | ||||
Overvoltage Protection | 112-132% of nominal output voltage on V1 only, recycle input to reset | ||||
Overload Protection | 110-150% of nominal power, with auto recovery | ||||
Short Circuit protection | Trip & restart (hiccup mode), auto recovery | ||||
Temperature Coefficient | 0.04%/°C | ||||
General | |||||
Efficiency | 80% typ, 230 VAC 100% load | ||||
Isolation | 3000 VAC Input to Output, 1500 VAC Input to Ground, 500 VAC Output to Ground | ||||
Switching Frequency | 60 kHz typical | ||||
Power Density | 3.5 W/In3 | ||||
Signals | Green DC OK LED | ||||
MTBF | 190 kHrs typical to MIL-HDBK-217F at 25 °C, GB | ||||
Environmental | |||||
Operating Temperature | 0 °C to +70 °C, derate linearly from 100% load at +50 °C to 50% load at +70 °C | ||||
Storage Temperature | -40 °C to +85 °C | ||||
Cooling | Convection-cooled | ||||
Operating Humidity | 5-95% RH, non-condensing | ||||
EMC and Safety | |||||
Emissions | EN55022, level B conducted and radiated | ||||
Harmonic Currents | EN61000-3-2, Class A | ||||
Voltage Flicker | EN61000-3-3 | ||||
ESD Immunity | EN61000-4-2, level 2 contact, level 3 air, Perf Criteria A | ||||
Radiated Immunity | EN61000-4-3, level 2, Perf Criteria A | ||||
Conducted Immunity | EN61000-4-6, level 2, Perf Criteria A | ||||
EFT/Burst | EN61000-4-4, level 2, Perf Criteria A | ||||
Surge | EN61000-4-5, installation Class 3, Perf Criteria A | ||||
Magnetic Field | EN61000-4-8, 1 A/m, Perf Criteria A | ||||
Dips & Interruptions | EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B | ||||
Safety Approvals | EN60950-1, UL60950-1, CSA60950-1 per cUL |
Model Number | Input | Output | Power | ||
SDS60 COVER KIT | Stock Check | ||||
SDS60UD04 | 90-264 VAC | +3.3V/7A +5V/5A | 48 W | ||
SDS60US03 | 90-264 VAC | 3-5V/16.6-10A | 50 W | Stock Check | |
SDS60UT03 | 90-264 VAC | +3.3V/5A +5V/5A +12V/1A | 53.5 W | Stock Check | |
SDS60US05 | 90-264 VAC | 5-6V/11-9.16A | 55 W | Stock Check | |
SDS60UQ06 | 90-264 VAC | +5V/1A +24V1/8A -15V/0.1A +12V/0.8A | 59.3 W | ||
SDS60US07 | 90-264 VAC | 6-8V/10-7.5A | 60 W | ||
SDS60UD01 | 90-264 VAC | +5V/7A +12V/3A | 63 W | ||
SDS60UQ00 | 90-264 VAC | +3.3V/6A +12V/3A -12V/0.8A -5V/0.8A | 63 W | ||
SDS60UQ01 | 90-264 VAC | +3.3V6A +12V/3A -12V/0.8A +5V/0.8A | 63 W | Stock Check | |
SDS60UQ02 | 90-264 VAC | +5V/6A +12V/3A -12V/0.8A -5V/0.8A | 63 W | Stock Check | |
SDS60UQ03 | 90-264 VAC | +5V/6A +12V3A -12V/0.8A +24V/0.8A | 63 W | Stock Check | |
SDS60UQ04 | 90-264 VAC | +5V/6A +12V/3A -12V/0.8A -24V/0.8A | 63 W | ||
SDS60UQ05 | 90-264 VAC | +5V/6A +15V/3A -15V/0.8A -5V/0.8A | 63 W | Stock Check | |
SDS60US09 | 90-264 VAC | 8-11V/7.87-5.72A | 63 W | Stock Check | |
SDS60US12 | 90-264 VAC | 11-13V/5.72-4.84A | 63 W | Stock Check | |
SDS60US15 | 90-264 VAC | 13-16V/4.84-3.93A | 63 W | Stock Check | |
SDS60US19 | 90-264 VAC | 16-21V/3.93-3A | 63 W | Stock Check | |
SDS60US24 | 90-264 VAC | 21-27V/3-2.33A | 63 W | Stock Check | |
SDS60US30 | 90-264 VAC | 27-33V/2.33-1.9A | 63 W | ||
SDS60US36 | 90-264 VAC | 33-40V/1.9-1.57V | 63 W | Stock Check | |
SDS60US48 | 90-264 VAC | 40-50V/1.57-1.26A | 63 W | Stock Check | |
SDS60UT00 | 90-264 VAC | +3.3V/6A +12V/3A -12V0.8A | 63 W | Stock Check | |
SDS60UT01 | 90-264 VAC | +3.3V/6A +12V/3A -5V/0.8A | 63 W | ||
SDS60UT02 | 90-264 VAC | +3.3V/6A +12V/3A +5V/0.8A | 63 W | ||
SDS60UT04 | 90-264 VAC | +3.3V/5A +5V/5A -12V/1A | 63 W | ||
SDS60UT05 | 90-264 VAC | +5V/6A +12V/3A -12V/0.8A | 63 W | Stock Check | |
SDS60UT06 | 90-264 VAC | +5V/6A +12V/3A -5V/0.8A | 63 W | Stock Check | |
SDS60UT07 | 90-264 VAC | +5V/6A +15V/3A -15V/0.8A | 63 W | Stock Check | |
SDS60UT08 | 90-264 VAC | +5V/6A +24V/2A -24V/0.5A | 63 W | Stock Check | |
SDS60UT09 | 90-264 VAC | +5V/6A +24V/2A -12V/0.8A | 63 W | Stock Check | |
SDS60UT10 | 90-264 VAC | +5V/6A +24V/2A +12V/0.8A | 63 W | Stock Check | |