Specifications | |
| Input |
| Input Voltage | | DLA50-A & -V: 90-264 VAC, All other models: 90-305 VAC |
| Input Frequency | | 47-63 Hz |
| Input Current | | 50 W: 0.70 A at 115 VAC, 0.35 A at 230 VAC, 75W: 0.9 A at 115 VAC, 0.40 A at 230 VAC, 120W: 1.38 A at 115 VAC, 0.7 A at 230 VAC, 150W: 1.8 A at 115 VAC, 0.80 A at 230 VAC |
| Inrush Current | | 60 A at 230 VAC, cold start +25 °C |
| Power Factor | | See table on datasheet |
| Earth Leakage Current | | 400 μA max at 115 VAC, 750 μA max at 230 VAC |
| Output |
| Output Voltage | | See table on datasheet |
| Initial Set Accuracy | | ±1% for -V versions, ±5% for -A versions |
| Minimum Load | | No minimum load required |
| Start Up Delay | | 3 s max at 100 VAC |
| Hold Up Time | | 10 ms minimum |
| Line Regulation | | ±1% maximum |
| Load Regulation | | ±3% maximum |
| Transient Response | | 5% max. deviation, recovery to within 1% in 10 ms for a 50% load change |
| Ripple & Noise | | 1.5% max pk-pk, 20 MHz bandwidth |
| Overvoltage Protection | | 110-140% Vnom, recycle input to reset |
| Overtemperature Protection | | Unit shuts down, recycle input to reset (Not on DLA50-A, -V or -VL) |
| Overload Protection | | 135% typical, auto recovery |
| Short Circuit Protection | | Trip and restart (Hiccup mode) |
| Temperature Coefficient | | 0.04%/°C |
| General |
| Efficiency | | See table on datasheet |
| Isolation | | DLA50-A & -V: (Class II) 3000 VAC Input to Output 3000 VAC Input to Case 500 VDC Output to Case All other models: (Class I) 3000 VAC Input to Output 1500 VAC Input to Ground 500 VDC Output to Ground |
| Switching Frequency | | PFC 30-90 kHz variable PWM 100-120 kHz typical |
| MTBF | | >300 kHrs to MIL-HDBK-217F at 25 ºC, GB |
| Environmental |
| Operating Temperature | | -35 °C to +60 °C for DLA50-A & -V, -35 °C to +55 °C for DLA50-VL -35 °C to +70 °C for others, DLA150 derate from 100% load at 65 °C to 90% load at 70 °C |
| Operating Humidity | | 5-100% RH, non-condensing |
| Storage Temperature | | -40 °C to +80 °C |
| Operating Altitude | | 3000 m |
| Shock | | 30 g, 10 ms on 3 axes |
| Vibration | | 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes |
| EMC and Safety |
| Emissions | | EN55022, Class B conducted and radiated |
| Harmonic Currents | | EN61000-3-2, Class C for DLA75,120 &?150 |
| Voltage Flicker | | EN61000-3-3 |
| ESD Immunity | | EN61000-4-2, 8 kV air and 4 kV contact, Perf Criteria A |
| Radiated Immunity | | EN61000-4-3, level 2 Perf Criteria A |
| EFT/Burst | | EN61000-4-4, level 2 Perf Criteria A |
| Surge | | EN61000-4-5, level 3 Perf Criteria B |
| Conducted Immunity | | EN61000-4-6, level 2 Perf Criteria A |
| Dips & Interruptions | | EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B |
| Safety Approvals | | EN61347, UL8750, CE Mark, some 50 W & 75 W models comply with UL1310 Class 2 requirement, see model table for details |