Modle | TLS-ZB100KW |
Input | Voltage Range | DC 100~500V |
Rated Voltage | DC 360V |
Control System | MPPT (Per channel maximum Idc = 10A, One or two arrays, a public independent MPPT) |
Output | Normal Output Capacity | 100KW |
voltage range | 3-phase (in accordance with the requirements of different countries and regions adjusted) |
Rated Voltage | 380VAC |
Normal Frequency | Grid-frequency 50/60Hz(can be set) |
Number of phases | 3-phase,4wires |
Power Factor | 0.95 |
Maximum Current | 263A |
THD | At rated power and in the sine wave <3.5% |
Efficiency | 97%(EuropeEfficiency:96.4%) |
Structure | Protection Class | IP20 |
Cooling System | Compulsary air-cooled system |
Noise | <60dB |
Data Interfaces | External RS 232C |
Protection | Inverter | Input overvoltage,output short circuit overload, overheat,output DC component. |
Grid | Anti-islanding(IEEE 1547),over/under voltage of grid, over/under frequency of grid. |
Environment | Operation temperature range | Ventilation via rear wall,-10℃~40℃(50℃) |
Stored temperature | -25℃~60℃ |
Relative humidity | <90%RH(Do not wet with dew) |
Environment | Have no corrosion gas, flammable gas,oil mist,dust etc. |
Standby power consumption | <250mW |
Altitude | 6600 feet (2000 meters) above derating |