商品介绍 型号 | TKF(R)-26GW | TKF(R)-32GW | TKF(R)-35GW | TKF(R)-60GW | TKF(R)-72GW |
电源220-240VAC, 1PH, 50/60Hz |
性能 | | |
能力 | 制冷 | Btu/h | 9000 | 11500 | 12000 | 20000 | 24000 |
W | 2600 | 3200 | 3500 | 6000 | 7200 |
制热 | Btu/h | 10000 | 12000 | 13000 | 22000+1700 | 27000+1700 |
W | 2900 | 3500 | 3800 | 6600+500 | 7900+500 |
噪音 | 内机 | dB(A) | ≤40 | ≤42 | ≤42 | ≤46 | ≤50 |
外机 | dB(A) | ≤50 | ≤50 | ≤52 | ≤56 | ≤58 |
循环风量 | m³/h | 450 | 520 | 550 | 850 | 1050 |
适用面积 | m² | 11~17 | 13~21 | 15~23 | 25~42 | 30~48 |
能效比 (EER) | W/W | 3.64 | 3.72 | 3.89 | 3.88 | 3.82 |
Btu/h/w | 12.42 | 12.69 | 13.27 | 13.24 | 13.03 |
能耗 |
输入功率 | 制冷 | W | 650~770 | 780~940 | 800~1025 | 1350~1560 | 1700~1900 |
制热 | W | 650~780 | 780~950 | 800~1050 | 1350~1590+500 | 1700~1950+500 |
额定电流 | 制冷 | A | 2.95~3.50 | 3.55~4.27 | 3.64~4.66 | 6.14~7.09 | 7.73~8.64 |
制热 | A | 2.95~3.55 | 3.55~4.31 | 3.64~4.77 | 6.14~7.23+2.2 | 7.73~8.66+2.2 |
真空管 | 直径*长度*根数 | 47mm*500mm*9 | 47mm*500mm*10 | 47mm*500mm*10 | 47mm*620mm*11 | 47mm*620mm*11 |
尺寸 |
内机 | 净尺寸 | mm | 700*230*160 | 785*285*210 | 785*285*210 | 985*320*215 | 985*325*230 |
包装 | mm | 822*315*250 | 910*370*300 | 910*370*300 | 1070*370*260 | 1070*370*260 |
外机 | 净尺寸 | mm | 610*260*520 | 790*260*540 | 790*260*540 | 850*300*755 | 940*300*755 |
包装 | mm | 670*360*600 | 910*370*610 | 910*370*610 | 950*400*770 | 990*400*770 |
保温桶 | 包装 | mm | 840*400*330 | 910*400*330 | 910*400*330 | 980*400*370 | 980*400*370 |
真空管 | 包装 | mm |
重量 |
内机 | 净/毛 | kg | 8/10 | 10.5/13 | 10.5/13 | 17/18.5 | 21/23 |
外机 | 净/毛 | kg | 27/32 | 38/40 | 38/40 | 50/52 | 55/58 |
集热器 | 净/毛 | kg | 12/13 | 13/15 | 13/15 | 16/17 | 16/17 |
参数表说明:
平板式集热器可供选择,安装更方便。 以上参数为在国家标准工况下测试的结果,即制冷时,室外干球/湿球温度为:35℃/24℃,室内干球/湿球温度为27℃/19℃;制热时,室外干球/湿球温度为:7℃/6℃,室内干球/湿球温度为20℃/15℃。实际数据会因使用环境不一样而发生变化。
表中红色数据表示电加热开启时的数据。
产品在设计、功能、性能等技术参数或外观结构等方面可能有所变动,网站上未能及时更新。请以产品铭牌为准,或向我们索取最新参数表。