安捷伦8509B光波偏振分析仪
安捷伦8509B光波偏振分析仪系统的个系统是一个提供校准的偏振的光信号的测量和组件。这些新功能提供创新的硬件,软件和数学。
硬件的贡献包括一个的四个二极管检测方案,包括1200纳米至1600纳米。单波长,1300和1550 nm的法布里 - 珀罗激光器,以及一个自动的三态偏振发生器中所提供内安捷伦8509B。也可用于外部单波长或波长扫描来源。
特点
两个自动偏振模色散(PMD)测量;琼斯矩阵本征分析和扫描波长IME的状态和偏振度的测量
快速,自动测量的光学元件中的偏振相关损耗
业务可联系朱小姐 手机13641431201,座机0755-23990060, QQ:2716209068,邮箱:wendyzhu@rmhk.net
AGILENT 8509B光波极化分析仪可对光信号或光器件进行校准过的极化测试。 这些功能是建立在硬件、软件和算法革新性突破的基础之上的.8509B可提供包括极化状态测试、极化模式色散测试、极化相关损耗测试和极化保偏光纤对准等功能。
特点:
1.对光信号和光器件进行全面的极化状态分析
2.两种PMD分析方法:波长扫描法和JONES矩阵法
3.极化保偏光纤的对准
产品名称: Agilent / HP 8509B Lightwave Polarization Analyzer
产品说明:现货1台。This Agilent / HP 8509B Lightwave Polarization Analyzer is used and in excellent condition.
Model 8509B:
1 Processor: AMD 6K/2 333 MHz
2 Hard Drive: 4GB HDD
3 Memory: 64 MB RAM
4 Operating Software on Controller: Windows 95 Installed
5 Installed Software: Agilent 8509 Lightwave Polarization Analyzer v2.11
6 Keithley PDMA-32 Parallel Digital Interface Board (Used to Interface Between 8509B and PC)
7 HP 82335A GPIB Card
8 Optical interface connectors: PC
9 Data Cable: 37-Pin E126286-C
10 Hardware Required: Monitor, Keyboard, Mouse
产品名称:光偏振分析仪
产品型号:8509B
厂商名称:惠普-HP
产品简述:The Agilent 8509B lightwave polarization analyzer offers highspeed,calibra-ted polarization measurements of both optical signals and components. These capabilities are provided by innovations in hardware, software,and applications of Jones matrix and Stokes vector mathematics.
The Agilent 8509B analyzer facilitates a greater understanding of the polarization properties of lightwave signals and materials in helping to develop higher performance light-wave components and systems, as well as more effective test and manufacturing processes.These developments involve many types of polarization-sensitive devices which are used in communications, sensors,optical computing and material analysis; devices such as single-mode fibers, polarization-maintaining fibers, isolators, optical switches,lasers, beamsplitters, modulators,
interferometers, retardation plates and, of course, polarizers and polarization adjusters.
Polarization characteristics affect all lightwave transmissions. The polarization of a lightwave signal is defined by its E-field components.As a signal propagates, interaction with optical components and other lightwave signals (in interferometric applications) modifies the magnitude and phase of the signal’s E-field components. Polarization-dependent loss, gain or even signal distortion may occur depending on theapplication.
Polarization mode dispersion is a key hurdle limiting the transmission of signals at 10 Gbit/s and above.The Agilent 8509B lightwave polarization analyzer in conjunction with the Agilent 8168 series tunable laser source or the Agilent 83432A temperature tuned DFB aser can be used to measure PMD of fiber and compo-nents down to 1 fs resolution.