Cryolipolysis Fat Dissolving Equipment
User Manual
Thank you for purchasing this product, please read the user manual carefully before using the equipment and keep it for viewing at any time.
Directory
A Product introduction ...........................................................................3
A1 security warning signs..........................................................................3
A2 features .................................................................................................3
A3 explanation ...........................................................................................4
A4 working principle ................................................................................4
A5 parameters ...........................................................................................4
B Equipment structure ..........................................................................5
B1 safe use .................................................................................................5
B2 equipment parts ...................................................................................6
B3 emergency switch diagram ..................................................................7
B4 vacuum handle suction diagram .........................................................7
C Operation steps ....................................................................................8
D Treatment notice ................................................................................10
E Security consideration .......................................................................11
E1 warning .................................................................................................11
E2 attention ................................................................................................11
E3 disabled people ......................................................................................11
F Main machine ...................................................................................12
F1 operating handles ................................................................................12
F2 screen interface ....................................................................................13
F3 inspection and maintenance ...............................................................15
G Warranty ........................................................................................15
A Product introduction
A1 Security warning signs.
External identifier pause
Pause working
High voltage danger Electric flag
A2 Features
. Current non-surgical medical beauty technology hot spots;
· Fat dissolving technology more advanced than liposuction;
· Novel the opposite of Europe's hottest diets;
· Area can be up to 26% of fat destruction technologies;
· Frozen cold grease. 40K, radio frequency melting fat blasting fat and fat body fat-soluble, with frozen new technologies;
· A selective up to reduce waist fat, back fat and fat micro-invasive technology;
A3 Explanation
For many years, people have been running out of ways cutting extra parts of the body fat, such as liposuction, laser melting fat, strong sound waves by blasting fat method, radio-frequency method of melting fat, Cryolipolysis frozen fat dissolving method and latest technology and heating instead of new and more efficient than other means of non-invasive methods.
A revolutionary new concept of melting fat. Use have since been proven to be in the weight loss fat dissolving a major victory in the war.
For those food and regular exercise, but is still not throwing off partial fat people, freezing melting fat is a godsend. Whether on lipid peroxidation of fats is also more intensive parts of smaller parts, such as the love muscle (on both sides of the waist above the hips loose dewlap), abdominal fat in belly and back, the freezing effect of melting fat are is dumbfounded.
A4 Working principle
Use of fatty acid and glycerol in three specific will be transformed into the characteristics of solid at low temperatures, transmitted through non-invasive transmitter wave to specify precise control at low temperature melting fat parts for and eliminate fat cells. After the fat cells in the cold, will start the natural decomposition of the purge process, fat layer becomes thin. Through normal metabolic processes, the fat layer gradually reduced, reach the purpose of partial melting fat.
A5 Parameters
Screen: 8 inch true color touch screen
Cavitation frequency :40Khz
RF :5Mhz multipolar RF
Input voltage :110V/220V 50HZ-60HZ
Input power :≤400W
Temperature :-5℃---0℃
B Equipment structure
The products mainly include the host, accessories (40K powerful sonic blast fat head, 5Mhz RF head, frozen fat head)
B1 Safe use
B2 Equipment parts
Vacuum valve: adjust the strength of negative pressure head size (screw clockwise to increase the strength, or counterclockwise twist is to reduce the intensity).
Cryolipolysis suction head output: connection freezing fat head.
Cooling fan : safety device, thermal absorption, and then spread to the outside of the chassis, ensure normal temperature for the host part.
Power switch: turn on the power switch, led lights, note instrument enters the standby state.
Fuse : insurance tube for protection.
40K focus on high acoustic output: connection 40K focus strong acoustic head.
5Mhz multipolar RF output: connect five radio head
Filter glasses: Please clean the filter regularly, and ensure that the normal use of the vacuum head.
Power Jack: connect the power cord.
B3 Emergency switch diagram
Emergency Swich Key Swich
On the line that corresponds to the connection to the power supply socket, turn on the power switch, led lights, note for standby instruments, turn the key switch, and finally to d-emergency switch, instrument status at this time.
B4 Vacuum handle suction diagram
Vacuum suction diagram Vacuum discharge intensity+ Vacuum suction intensity+ Vacuum discharge intensity- Start /pause Vacuum suction intensity-
C Operation steps
Step 1:operate the cavitation handle set the working time about 10-15 minutes. Choose the best intensity depends on the client's feelings Press the start and start get in the cavitation treatment。 Operated over, return the main interface choose next function。 | |
Step2:5Mhz multipolar RF,set the working time about 10-15 minutes. Choose the best RF intensity depends on the client's feelings ,Press the start and start get in the RF treatment。 Operated over, return the main interface choose next function。
| |
Step3:Cryolipolysis suction head operate, Gap along the bags open with her hands freezing film 。 | |
Hold the freezing film | |
Put the freezing film on the treatment area。 | |
Adsorption treatment of head in the treatment position, first open the start key on the Control Panel, and then open the start of negative pressure on the handle, Negative-pressure heads into a working state, to set good working time (15 minutes), choosing the required strength, Strength is subject to customers under. Click on the "start" key to enter the State.
| |
Hit the fat layer deep inhalation in the treatment of head
| |
Remove the treatment, treatment of silt parts appear red. Zero intensity, operation is complete.
|
D Treatment notice
1.Therapy probes must be close contact with the skin.
2.Hairdresser when you adjust the strength, good communication with the customer.
3.When the operation is finished, clean the skin with hot towels.
4.When nursing to a circle or a straight line motion, don't stay in the same position. Action or pull up to coherence.
E Security consideration
E1 Warning
1.Connected or disconnected vacuum head when disconnected, the close connection duct on the left hand, right hand hold metal parts, to rotate in the counterclockwise direction (as shown in the figure on the left). When connected, close connection duct on the left hand, right hand hold metal parts, to rotate in the clockwise direction.
2.In the heat of the summer, freezing probe after half an hour of work, if there is a freezing of unsatisfactory circumstances, proposal to inject water or ice in the water into the tank into the condensing agent (refrigerant), ensure that the ice can achieve better cooling effect.
3.Instrument belongs to the high-precision electronic instruments, custody and placement of time, must not be placed in a wet place.
4.The instruments used in all automatic operation control chip, so when in use, around and try not to use high frequency electronics, so as not to interfere with the normal operation of the equipment used. (Like volume, hair dryer, microwave instruments, etc). If interference occurs, there are two kinds of phenomenon (a. normal use when sudden panic b. LCD appears jumping), the general solution is to turn off the power source and restart the instrument.
5.You can't put up with setbacks, strong impact.
6.Instrument host and accessories needs regular cleaning and care, especially do not let water into the main instrument.
7.If not for a long time, it is best to use a damp-proof bag and dust protection instruments as a whole, best power up about 15 days work for an hour, so that electronic devices inside the wet aged.
E2 Attention
Prohibited uses under the following circumstances:
1)power plug wire is broken or when hot;
2)when Jack is loose or shaking;
3)against damaged, machining, bending, twisting the plug;
4)operations which do not just pull the plug;
5)prohibit the use of other power cord;
6) place Baby, children can not reach;
7)Prohibition of the chemicals used to clean the instrument.
8) prohibiting plug plug with wet hands;
E3 Disabled people
1, skin wounds, avoid the wound or not.
2, epileptics are banned.
3, in patients with heart disease (such as irregular heartbeat), especially with cardiac pacemakers are banned.
4 patients with infectious diseases, cancer patients do ban, ban.
6, pregnant women do ban.
7, major surgery, diabetes patients forbidden to do.
8, any metal in the body. forbidden to do.
9, female physiological cycles, it is best to not do.
F Main machine
Accessory | images |
40K Cavitation | |
5Mhz multipolar RF
| |
Bipolar RF Face | |
Cryolipolysis suction head | |
Cryolipolysis suction head | |
Funnel to watering |
F1 operating handles
F2 screen interface
F3 inspection and maintenance
1.Each parts belong to the precision of the device, and when completed, be sure to pay attention to maintenance, so as to avoid their shorten service life.
2.Fittings to handle with care, be sure to note with a handle, don't randomly carried out line, easily fitting inside the connector is loose, resulting in poor contact and short circuit.
3.Parts used is completed, do not randomly drop, should carefully clean with a clean liquid combined with clean touch cloth, placed on the gallows. Recommended saline solution or a little cleaner for surface cleaning.
4.40K strong and explosive fat head time to 30 minutes of continuous work, when after 30 minutes of work, probes should be allowed to rest for 5 minutes, until surface temperatures lower, then continue to use, when the accessories when not in use, be sure to remove the parts, put on the gallows in must not allow it to dry, so as not to burn out the probe.
5.Freezing fat head: you must pay attention to clean, complete, when it finds a host of essential oil in the filter or full time, be sure to clean your filter product, so as not to affect the suction.