Preface
Version description:
This manual belongs to version V2.0 of kingwee PSE series remote line power supply.
Series description:
1. PSE01 series remote power supply.
2. PSE04 series remote power supply.
3. PSE08 series remote power supply.
4. PSE16 series remote power supply.
5. PSE24 series remote power supply.
Target reader:
This manual is for users of kingwee PSE series remote line power supply.
Relevant manual:
This manual belongs to theInstallation Manualof king wee PSE series remote line power supply.
Text structure:
The basic information of this manual is listed below, including the chapter names and main use purposes.
Chapter 1 System Overview Describe the system features of king wee PSE remote line power supply.
Chapter 2 Structure and Electrical Connection Describe the appearance and pin definition of kingwee PSE remote line power supply.
Chapter 3 Installation and Commissioning Describe the installation and commissioning of king wee PSE remote line power supply.
Chapter 4 Daily Maintenance Describe the problems needed to be pay attention during the daily maintenance of king wee PSE remote line power supply.
Chapter 5 Transportation and Storage Describe the problems needed to be pay attention during the transportation and storage of TBCOM PSE remote line power supply.
CONTENTS
Chapter 1 System Overview.1
1.1 Features and functions.1
1.2 Operational environment1
1.3 Technical features and parameters.1
Chapter 2 Structure and Eletrical Connection.3
2.1 Structure appearance ofTBCOM PSE remote line power supply.3
2.2 Interface description. 4
Chapter 3 Installation and Commissioning.5
3.1 Open-case inspection.5
3.2 Installation.5
3.3 Startup test5
Chapter 4 Daily Maintenance.6
4.1 Daily maintenance and care.6
Chapter 5Transportation and Storage.7
5.1 Transportation.7
5.2 Storage.7
This chapter includes
² Features and functions
² Operational environment
² Technical features and parameters
This chapter describes the features and functions of TBCOM PSE series remote power supply equipments.
1.1 Features and functionskingwee PSE series remote line power supply is a remote power supply specially designed and developed by Shenzhen kingwee Communication Technology Co., Ltd. This power supply is for indoor use and can work normally within the input voltage of 165VAC – 280VAC. It is connected with the network equipment (such as LAD or WLAN) through category 5 cable.
kingwee PSE series remote line power supply has the following performance:
(1) The power supply has such functions as input over/under-voltage protection, output over-voltage protection, overheating protection and over-current and short circuit protection for each output.
(2) System reliability: MTBF>100k hours.
(3) Conducted emission (CE) and radiated emission (RE) conform to EN55022 and CLASS B standards.
(4) Lightning protection feature: AC input end is able to bear 5KA and 8/20uS striking current waveform. Five times for positive pole and negative pole respectively with an interval of one minute each time; power lightning protection circuit has fault alarm function and is equipped with safety protection elements such as protective tube.
(5) Noise:<38dB
1.2 Operational environment(1) Environmental temperature: -5℃~+55℃
(2) Relative humidity: 5%~90%RH
(3) Operate in a ventilated, radiating and clean place which is free from conductive dust and corrosive gas.
1.3 Technical features and parameters(1) Input voltage: 165VAC~280VAC and 47Hz~63Hz
(2) Maximum output power:
PSE24: 300W; maximum one-way output power: 36W (high-power model)
PSE16: 300W; maximum one-way output power: 36W (high-power model)
PSE12: 300W; maximum one-way output power: 36W (high-power model)
PSE24: 150W; maximum one-way output power: 36W
PSE16: 150W; maximum one-way output power: 36W
PSE12: 150W; maximum one-way output power: 36W
PSE08: 150W; maximum one-way output power: 36W
PSE04: 100W; maximum one-way output power: 36W
PSE01: 36W; maximum one-way output power: 36W
(3) Voltage/current for each output: -52VDC/750mA (MAX)
(4) Output voltage regulation precision: -52VDC±5%
(5) Load regulation: -52VDC±5%
(6) Temperature range for working environment: -5℃~+55℃
(7) DC output noise voltage:
Psophometrically weighted noise ≤2mv
Broad frequency noise voltage:
A.3.4kHz~150kHz≤50mv
B.0.15MHz~30MHz≤20mv
Discrete frequency noise voltage:
A.3.4KHz~150KHz≤5mv
B.150KHz~200KHz≤3mv
C.200KHz~500KHz≤2mv
D.0.5MHz~30MHz≤1mv
(8) Dimension and weight:
| PSE01 | PSE04 | PSE08 | PSE12 | PSE16 | PSE24 |
Way | Way 1 | Way 4 | Way 8 | Way 12 | Way 16 | Way 24 |
Width | 58mm | 270mm | 270mm | 436mm | 436mm | 436mm |
Height | 38mm | 44mm | 44mm | 44mm | 44mm | 44mm |
Depth | 120mm | 170mm | 170mm | 210mm | 210mm | 210mm |
Weight | <1kg | <2.5kg | <3kg | <4kg | <4.5kg | <6kg |
(9) Protective functions for remote power supply of TBCOM PSE series:
A. Over-current protection (one-way): 750mA~1000mA
B. Over-voltage protection: Input voltage exceeds 290VAC to 310VAC.
C. Over-voltage recovery point: Input voltage exceeds 285VAC.
D. Under-voltage protection: Input voltage is less than 140VAC to 155VAC.
E. Under-voltage recovery point: Input voltage exceeds 165VAC.
F. Over-temperature protection:>100℃
Chapter 2 Structure and Electrical Connection
This chapter includes
² kingweePSEstructure appearance.
² Interface standard
This chapter mainly introduces kingwee PSE’s structure and connection method.
2.1 Structure appearance of kingwee PSE series remote line power supply
kingweePSE24
kingweePSE16
kingweePSE12
PSE08
PSE04
PSE01
Light of network port instruction:
When the PWR light is on, it means the power supply is working under normal conditions.
When the port light is on, it means the power is supplied under normal conditions. If the indicator light goes out after several seconds, it means the equipment is under over-voltage protection or short circuit occurs.
2.2 Interface descriptionPin configuration of the network port:
RJ45 socket |
Definition of network port connection:
RS232 serial ports RJ-45 pin definition | Ethernet RJ-45 pin definition | Power supply RJ-45 pin definition | |||
Pin | Signal definition | Pin | Signal definition | Pin | Signal definition |
1# | — | 1# | Rx+ | 1# | Rx+ |
2# | — | 2# | Rx- | 2# | Rx- |
3# | TXD | 3# | Tx+ | 3# | Tx+ |
4# | GND | 4# | — | 4# | -48V RTN |
5# | GND | 5# | — | 5# | -48V RTN |
6# | RXD | 6# | Tx- | 6# | Tx- |
7# | — | 7# | — | 7# | -48V |
8# | — | 8# | — | 8# | -48V |
This chapter includes
² Open-case inspection
² Installation
² Startup test
This chapter mainly introduces the common operation for installation and commissioning of TBCOM PSE series remote line power supply.
3.1 Open-case inspection1. Open case to see whether all the accessories have been included. They are:
User’s manual (one).
Input power cord (one).
2. Inspect the main body to see if there is any damage, deformation and rust.
If you find that the type and number of the equipment parts are not in line with what is described, or equipment damage occurs during transportation, contact our company immediately to take effective measures.
3.2 Installation(1) Insert the input power cord to the dc input socket of 220VAC.
(2) Connect with output signal line respectively (see figure 2-4).
(3) Ensure the incoming line, signal line and output line are securely connected to the equipment to avoid poor contact or loose.
iNotices:
u Notice 1: The place where the remote power supply is installed should be far away from heat producer and electromagnetic interference source, and free from corrosive gas and metal dirt.
u Notice 2: The heat dissipation hole should not be clogged.
u Notice 3: The equipment should be laid in a stable place without strenuous vibration during installation.
u Notice 4: Keep an eye on the range of ac input voltage to ensure it is between165VAC and 280VAC.
u Notice 5: Prevent collision and friction with other equipments during installation to avoid surface’s local damage.
3.3 Startup test(1) Use a multimeter to test the ac input voltage to avoid short circuit; After loading, if the indicator light of the output interface is green, it means the equipment is working under normal conditions; if the light goes out after several seconds, it means short circuit or current limitation occur.
(2) The light on the front panel will be on after the ac power is connected.
Chapter 4 Daily MaintenanceThis chapter includes
² Daily maintenance and care
This chapter mainly introduces the operation for daily maintenance and care of kingwee PSE series remote line power supply.
4.1 Daily maintenance and carekingwee PSE series remote line power supply can work constantly. In order to ensure the reliability of power supply, daily maintenance should be carried out properly to ensure the power supply system works under optimum state.
(1) Clean the power supply system regularly to avoid dirt retention.
(2) Inspect the input line and output line to see if any loose or poor contact occurs. Replace the line immediately if any damage is found.