Features | | | | | | | |
• Compliant with Isolation and Channel | | • Data and Power carried over one Cable |
Characteristics of IEEE802.3af | | | | | | |
• DC Good LED | | | | • Full Protection- OCP, OVP | |
• Non-Vented Case | | | | | | | |
Applications | | | | | | | |
• IP Telephones | | | | • Security Camera | |
• Wireless Network ess Points | | | • IP Print Servers | |
• Blue Tooth ess Point | | | | | | |
Safety Approvals | | | | | | |
• CE | | | | | | | | |
Mechanical Characteristics | | | | | |
• Length: 123mm | | | | • Height: 40mm | | |
• Width: 61mm | | | | • Weight: 0.2Kg | | |
Output Specifications | | | | | | |
| | | | | | | | |
Model | DC Output Voltage | Load | Regulation |
GRT-480050 | 48V | Min. | Max. | Line | Load |
0A | 0.5A | ±4% |
| | | | | | | | |
Ripple And Noise* | Vp-p* | | | | | | |
<500Hz | 0.5 | | | | | | |
500Hz-150KHz | 0.5 | | | | | | |
150KHz-500KHz | 0.5 | | | | | | |
500KHz-1MHz | 0.5 | | | | | | |
Great is not responsible for any error and change. Content is subject to change without notice. |
Please consult the factory andvisit for the most up-to-date specifications. |
| | | | | | | | |
GRT-480050 Characteristics | | | | |
INPUT: | | | | | | | |
AC Input Voltage Range | | | EMC | | | |
90 to 264VAC | | | | Part 15 Class B | |
AC Input Voltage Rating | | | EN55022 Class B | | |
100 to 240VAC | | | | Isolation Test | | |
AC Input Current | | | | Primary to Secondary: 3000VAC for 1 minute 10mA |
0.5A(RMS) max. for 90VAC | | | Primary to F.G.: 1500VAC for 1 minute |
0.35A(RMS) max. for 240VAC | | | Output to F.G.: 1500VAC | |
Leakage Current | | | | Immunity EN50082-1 | |
0.25mA max. @ 254VAC 60Hz | | | ESD: EN61000-4-2. Level 3 | |
AC Input Frequency | | | | RS: EN61000-4-3. Level 2 | |
47-63Hz | | | | | EFT: EN61000-4-4. Level 2 | |
AC Inrush Current | | | | Surge: EN61000-4-5. Level 3 | |
15A(RMS) max. for 115VAC | | | CS: EN61000-4-6. Level 2 | |
20A(RMS) max. for 230VAC | | | Voltage Dips EN61000-4-11 | |
OUTPUT: | | | | | Harmonic: EN61000-3-2 | |
Total Output Power | | | | Insulation Resistance | |
24W | | | | | Primary to secondary: >10M OHM 500VDC |
Efficiency | | | | Primary to FC: >10M OHM 500VDC | |
80% (typical) at Max. load, and 120VAC 60Hz | | FEATURE: | | |
Hold-up Time | | | | Over Voltage/Current, Short Circuit Protection |
16mS min. 120VAC and max. load | | | The output can be shorted permanently without damage |
Transient O/P Voltage Protection | | Indicators | | |
60V max. at switch on and off at any AC line Phase | Led #1 indicator for input power “on” GREEN |
ENVIRONMENTAL: | | | | Input Connector | | |
Temperature | | | | IEC320 inlet 3 pin | | |
Operation 0 to +40°C | | | | Data Connector | | |
Non-operation -25 to +65°C | | | RJ45 +48V pins4&5, Power Return pins7&8 |
Humidity | | | | | | | | |
Operation 5 to 90% |