供应P12户外全彩LED显示屏-厂家低价直供7000元/平米起
像素间距 | 像素密度 | 像素规格 | 模组尺寸 | 模组分辨率 | 虚拟像素 | 重量 | 亮度 | 视角 | 视距 | 防护等级 | 无故障时间 |
P3 mm | 62500 pixels/㎡ | ?3mm | 260x130x45mm | 64x32mm | 无 | ≤46kg/ ㎡ | ≥6000nits | 110/40deg. | ≥1m | IP 65 | 1000h |
P3.75 mm | 44100 pixels/㎡ | ?3.75mm | 304x152x45mm | 64x32mm | 无 | ≤46kg/ ㎡ | ≥6000nits | 110/40deg. | ≥2m | IP 65 | 1000h |
P5 mm | 17222 pixels/㎡ | ?5mm | 484x242x45mm | 64x32mm | 无 | ≤46kg/ ㎡ | ≥6000nits | 110/40deg. | ≥3m | IP 65 | 1000h |
P10 mm | 10000 pixels/㎡ | (2R/1R) | 320x160x45mm | 32x16mm | 无 | ≤46kg/ ㎡ | ≥6000nits | 110/40deg. | ≥10m | IP 65 | 1000h |
P12 mm | 6944 pixels/㎡ | (2R/1R) | 192x96x45mm | 16x8mm | 无 | ≤46kg/ ㎡ | ≥6000nits | 110/40deg. | ≥12m | IP 65 | 1000h |
P16 mm | 3906 pixels/㎡ | (2R/1R) | 256x256x45mm | 16x16mm | 无 | ≤46kg/ ㎡ | ≥6000nits | 110/40deg. | ≥16m | IP 65 | 1000h |
P20 mm | 2500 pixels/㎡ | (2R/1R) | 320x160x45mm | 16x8mm | 无 | ≤46kg/ ㎡ | ≥6000nits | 110/40deg. | ≥20m | IP 65 | 1000h |
P25 mm | 1600 pixels/㎡ | (2R/1R) | 200x200x45mm | 8x18mm | 无 | ≤46kg/ ㎡ | ≥6000nits | 110/40deg. | ≥25m | IP 65 | 1000h |
一、显示屏常见问题及解决方法 :
故障现象 | 故障原因 | 故障分析处理 |
1、整屏不亮或出现方格 | 1、控制主机是否开启 2 、通讯线是否插好 3 、发送卡是否已插好 4 、多媒体卡与采集卡 , 发送卡之间的数据线是否连好 5 、接收卡 JP1 或 JP2 开关位置不对 | 打开主机 把通讯线插好 把发送卡重插 连好多媒体卡与采集卡 , 发送卡之间数据线. 调整好 JP1 ,JP2 开关位置 |
2、每次启动 LED 演播室时提示找不到控制系统 | 1、COM 口至数据发送卡之间的信号采集线没有连接或电脑本身 COM 口已坏。 | 连接好该数据线或更换电脑 |
3、整屏隔十六行数据闪或常亮 | 1、检查 LED 演播室里的设置 | 打开 LED 演播室打开调试 - 硬件设置(密码 168 )-系统设置,把行顺序设置为 +0 或 +1 |
4、整屏画面晃动 或重影 | 1、检查电脑与大屏之间的通讯线 2 、检查多媒体卡与发送卡的 DVI 线。 3 、发送卡坏。 | 把通讯线重插或更换 把 DVI 线冲插加固 更换发送卡 |
二、驱动部分
故障现象
| 故障原因 | 故障分析处理 |
1、一单元板不亮 | 1、 +5V 电或 GND 是否供给 2 、 +5V 跟 GND 是否短路 3 、 138 第五腿的 OE 信号是否有 4 、 245 相连的 OE 信号是否正常(断路或短路); | 给上 +5V 电或 GND 把短路的给断开 把 OE 信号供上 把断路的连好把短路的给断开 |
2、一单元板上半部分或下半部分不亮或显示不正常 | 1、 138 的第 5 腿 OE 信号是否有; 2 、 74HC595 的第 11 、 12 腿的信号是否正常;( SCLK 、 RCK ) 3 、相连的 OE 信号是否正常;(断路或短路) 4 、双排插针与 245 相连的 SCLK 、RCK 信号是否正常;(断路或短路) | 把 OE 信号连上 把 SCLK 、 RCK 信号连好 把断路的连好把短路的断开 把断路的连好把短路的断开 |