WIKA TR12-B TR12-M 过程热电阻温度计 配保护套管 防爆Ex d Ex i
Process resistance
thermometer
Model TR12-B, for additional thermowell
Model TR12-M, basis
module
Fig. left: Process resistance thermometer model
TR12-B
Fig. right: Basis module model TR12-M
Applications
■
Chemical industry
■ Petrochemical industry
■ Offshore
■
Plant and vessel construction
Special features
■ For many variants of
temperature transmitters with field transmitter
■ For mounting in all
standard thermowell designs
■ Spring-loaded measuring insert
(replaceable)
■ Explosion-protected versions Ex d, Ex i
Description
Resistance thermometers in
this series can be combined with a large number of thermowell designs. The
replaceable, centrically spring-loaded measuring insert and its extended spring
travel enable combination with the widest range of
connection head
designs.
A wide variety of possible combinations of sensor, connection
head, insertion length, neck length, connection to thermowell etc. are available
for the thermometers; suitable for any thermowell dimension and any
application.
Specifications
Neck
tube versions
Measuring insert
The exchangeable measuring insert is made
of a vibrationresistant sheathed measuring cable (MI cable).
The diameter
of the measuring insert should be approx. 1 mm smaller than the bore diameter of
the thermowell. Gaps of more than 0.5 mm between thermowell and the
measuring
insert will have a negative effect on the heat transfer, and they will result in
unfavourable response behaviour from the thermometer.
When fitting the
measuring insert into a thermowell, it is very important to determine the
correct insertion length (= thermowell length for bottom thicknesses of ≤ 5.5
mm). The measuring insert should be spring-loaded (spring travel: 0 ... 20 mm)
in order to ensure that it presses against the bottom of the
thermowell.
Neck
tube
The neck tube is screwed into the connection head or
the case. The neck length depends on the intended use. Usually an isolation is
bridged by the neck tube. Also, in many cases, the neck tube serves as a cooling
extension between the connection head and the medium, in order to protect any
possible built-in transmitter from high medium temperatures.
In the Ex d
version the flameproof joint is integrated in the neck tube.
Thermowell selection
Transmitter (option)
Explosion protection
For application in hazardous areas,
corresponding versions are available.
Intrinsic safety
The instruments comply with the
requirements of 94/9/EC
(ATEX) directive for gas.
Flameproof enclosure
These instruments comply with the requirements of 94/9/EC (ATEX) directive or
IECEx for gas.
The classification/suitability of the instrument
(permissible power Pmax as well as the permissible ambient temperature) for the
respective category can be seen on the EC typeexamination certificate or on the
IECEx certificate and in the operating instructions.
Built-in transmitters have their own EC
type-examination certificate. The permissible ambient temperature ranges of the
built-in transmitters can be taken from the corresponding transmitter
approval.
Functional safety (option)
In
safety-critical applications, the entire measuring chain must be taken into
consideration in terms of the safety parameters. The SIL classification allows
the assessment of the risk reduction reached by the safety installations.
Selected TR12 process resistance thermometers in combination with an appropriate
temperature transmitter (e.g. model T32.1S) are suitable as sensors for
safety
functions up to SIL-2.
Matched thermowells allow easy
dismounting of the measuring insert for calibration. The optimally tuned
measuring point consists of a thermowell, a TR12
thermometer and a T32.1S
transmitter developed in accordance with IEC 61508. Thus, the measuring point
provides maximum reliability and a long service life.
Electrical
connection
(Colour code per IEC 60751)
Ordering
information
Model / Explosion protection / Ignition
protection type / Sensor / Sensor specification / Thermometer operating range
/ Terminal box / Thread size at the cable entry / Cable entry / Transmitter /
Neck tube version / Connection to housing, connection head / Connection to
thermowell / Neck tube length N(MH) / Insertion length A / Measuring insert /
Options
欢迎致电咨询订购WIKA TR12-B TR12-M 过程热电阻温度计 配保护套管 防爆Ex d Ex i
电话:010-51669912 56291930 15910733293
传真:010-51669912
QQ:823377546 1491421115 2636968574
邮箱:sales@zoriver.cn