【Mini 1U Single】P1S-2500V48


500W

Server ,Workstation ,Storage System ,IPC ,Blade server

150x81.5x40.3(mm)
5.91x3.21x1.59(inch)
VOLTAGE: 180~264VAC
FREQUENCY: 47~63HZ
INPUT CURRENT:6.5A (RMS) FOR 115 VAC / 3.5A (RMS) FOR 230 VAC
INRUSH CURRENT:80A @230 VAC PER MODULE
Output VoltageTD | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+48V | 1 | 10.4 | ±5% | ±1% | 480mV |
+5VSB | 0.1 | 2.5 | ±5% | ±1% | 50mV |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
* TOTAL OUTPUT MAX: 500W * TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:87.8% AT 230VAC, FULL LOAD
* LEAKAGE CURRENT: 3.5MA. MAX. AT NOMINAL VOLTAGE 240VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~160% MAX
* OVER VOLTAGE PROTECTION: +48V→52.8 ~ 62.4V
* SHORT CIRCUIT PROTECTION: +48V, +5VSB
* SAFETY: MEET UL, CUL, TUV, CCC
* REMOTE ON/OFF CONTROL
* WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.