 |  |  |  340.00422.0043.00 (mm) 13.39x16.61x3.27 (inch) | |
|  VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT (PER POWER MODULE):19/8A FOR 115/230VAC INRUSH CURRENT (PER POWER MODULE):40/60A MAX. FOR 115/230VAC (25℃) | |
|
|
|  | Output Voltage | Output Current Min. | Output Current Max. | Output Current Peak | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] | +5V | 1.5 | 60.00 | | ±5% | ±1% | 50mV |
|
|  |
|  |
|  |
|  |
|  |
|  |
|  |
|  |
|  |
 | * TOTAL MAX OUTPUT OF +5V AND +3.3V NOT EXCEED 380W. * TOTAL OUTPUT MAX: 1250W. |  * TEMPERATURE RANGE:OPERATING 0℃~45℃, STORAGE -20℃~80℃ * HOLD UP TIME:16mS IN REGULATOIN LIMIT AT 90VAC INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO frame GROUND 1500 VAC FOR 1 MINUTE * EFFICIENCY:>80% AT 115VAC, 30%~100% MAX LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500Ms * OVER POWER PROTECTION: 110~160% * OVER VOLTAGE PROTECTION:+3.3V→3.9V~4.7V,+5V→5.7V~6.5V ,+12V→12.8 V~13.9V * OVER CURRENT PROTECTION: +5V,+12V,+3.3V 110~ 160% AT FULL LOAD * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V * REMOTE ON / OFF CONTROL * BALANCE LOAD SHARING DESIGN * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION * ISOLATION: BUILT-IN THE POWER MODULE * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL * COOLING:38*28mm, TWO DC FAN (PER MODULE) * EMI NOISE FILTER: FCC CLASS B , CISPR 22 CLASS B * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC) * SAFETY:TO MEET UL, TUV, CB IEC60950
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |
|
|
|
|