| | | 265.00x101.00x84.00 (mm) 10.43x3.98x3.31 (inch) | |
| VOLTAGE: 90 ~ 264 VAC FULL RANGE. FREQUENCY: 47 ~ 63 Hz. INPUT CURRENT: 4A (RMS) FOR 230 VAC 8A (RMS) FOR 115 VAC INRUSH CURRENT: 35A MAX. FOR 115 VAC PER MODULE 40A MAX. FOR 230 VAC PER MODULE POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% AT 230V, FULL LOAD | |
|
|
| | Output Voltage | Output Current Min. | Output Current Max. | Output Current Peak | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] | +5V | 0.5 | 24.00 | | ±5% | ±1% | 70mV |
|
| |
| ‧TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃ ‧HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE ‧EFFICIENCY: 80% TYPICAL AT 115VAC, FULL LOAD ‧POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms ‧OVER POWER PROTECTION ‧OVER VOLTAGE PROTECTION ‧OVER CURRENT PROTECTION ‧SHORT CIRCUIT PROTECTION ‧SAFETY: TO MEET UL, TUV, CB ‧EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A ‧3.3V REMOTE SENSING ‧DIMENSION: 265 (D) x 101 (W) x 84 (H) mm
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |
|
|
|
|