【1U Single】P1U-5400E
400W
Server ,Workstation ,Storage System ,IPC
190x100x40(mm)
7.48x3.94x1.57(inch)
VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 8/3 AMPS MAXIMUM AT ANY LOW/HIGH
RANGE INPUT VOLTAGE.
INRUSH CURRENT: 15/30 AMPS @115/220 VAC
(AT 25 DEGREES AMBIENT COLD START)
Output VoltageTD | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 0.1 | 18 | ± 5% | ± 1% | 60mV |
+12V | 0.1 | 32 | ± 5% | ± 1% | 120mV |
-12V | 0.1 | 0.5 | ± 5% | ± 1% | 120mV |
+3.3V | 0.1 | 18 | ± 5% | ± 1% | 50mV |
+5VSB | 0.1 | 3 | ± 5% | ± 1% | 50mV |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
REMARKS:
1.TOTAL MAX OUTPUT OF +5V AND +3.3V NOT EXCEED 105W
2.POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 400W
* TEMPERATURE RANGE: OPERATING 0℃ ~ 45℃, STORAGE -20℃~80℃
* EFFICIENCY: POWER SUPPLY EFFICIENCY TYPICAL 88%(+/-2) AT 115V,FULL LOAD.
* HOLD UP TIME: WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* HUMIDITY:OPERATING:20%-80%, NON-OPERATING:10%-90%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
* OPP / OVP / SCP
* LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250 VAC
* SAFETY: TO MEEET UL, CUL, TUV, CCC
* REMOTE ON/OFF CONTROL
* ErP READY
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.