| 型 号 |
KY-50W-05-L | KY-100W-05-L | KY-150W-05-L | KY-240W-25-LFAN | | | |
直流输出电压 | 5V | 5V | 5V | 24V | | | |
输出电压容差 | ±2% | ±2% | ±1% | ±1% | | | |
额定输出电流 | 10A | 20A | 30A | 10A | | | |
输出电流范围 | 0~10A | 0~20A | 0~30A | 0-10A | | | |
纹波及噪音 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | | | |
进线稳定度 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | | | |
负载稳定度 | ±1% | ±1% | ±0.5% | ±0.5% | | | |
直流输出功率 | 50W | 100W | 150W | 240W | | | |
效率 | 83% | 80% | 81% | 83% | | | |
直流电压可调范围 | 4.5-5.6V | 4.5-5.5V | 4.5-5.5V | 24.5-25V | | | |
输入电压范围 | 90~132VAC/180~264VAC由开关选择47-63Hz;254-370VDC |
输入电流 | 6.5A/115v 50A/230V |
冲击电流 | 25A/115A 50A/230A |
漏电流 | <3.5mA/240VAC |
过载保护 | 105%~135%类型:切断输出 复位:自动恢复 |
过电压保护 | 5.75-6.75V 9.4-10.9V 13.8-16.2v 15.5-18.2V 18-21V 27.6-32.4V 33.7-39.2V 57.6-67.2V |
高温保护 | RTH3≥650C-700C风扇起动,≤550C风扇关闭,≥800C-850C切断输出(5-15V)-(24-48V) |
温度系数 | ±0.03%/℃(0~50℃) |
启动、上升、保持时间 | 200ms,50ms,20ms |
抗震性 | 10~500Hz,2G 10min,/1周期,时长60分,各轴 |
耐压性 | 输入输出间:1.5KvAC输入与外壳;1.5KvAC输出与外壳;0.5KvAC |
隔离电阻 | 输入输出间,输入与外壳,输出与外壳:500VDC/100MΩ |
工作温度、温度 | -10℃~+50℃,20%~90%RH |
存储温度、温度 | -20℃~+85℃,10%~95%RH |
外形尺寸 | 198×110×50mm |
重量 | 0.75Kgs |
安全标准 | 设计标准UL1950 |