The Switched Cabinet CDU CW-32VD2/E combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.
This Sentry PIPS CDU combines all of the features of a Switched CDU with the ability to provide power monitoring per inlet/infeed. Power information per infeed includes current, voltage, power, apparent power, crest factor, reactance, power factor and accumulated energy.
This information replaces branch circuit monitoring devices typically installed in the power distribution panel or remote power panel (RPP) with higher accuracy and lower cost monitoring of each circuit attached to the CDU.
Combine the Sentry PIPS Switched Cabinet PDU with the Sentry Power Manager software tool to gain power usage information across multiple Cabinet PDU's inpidual IP address.
Only our Switched Cabinet PDU products provide the flexibility needed for all data centers and remote sites; including support for 20-amp or 30-amp power input, 208-240V or European 230V configuration; UL 60950-1 branch circuit protection; EN 60950-1:2001; SSL & SSH security; and SNMP-based input current monitoring. For cabinets with high-density servers, this cabinet distribution unit delivers unparalleled remote management solutions.
产品图片:


| Sentry Cabinet PDU Specifications | |||||
| Item # | Available Input Voltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
| Switched CW-32VD/E with PIPS | |||||
| CW-32VD2AA15A1 CX-32VD2AA15A1* | 208-240V 50/60Hz | 20A | Dual IEC C20 Inlets, Bottom/Frt Entry | (24) IEC 60320/C13 (8) IEC 60320/C19 | 42.0 x 3.5 x 3.5 in. (1067 x 89 x 89 mm) |
| CW-32VD2CA15A1 CX-32VD2CA15A1* | 208-240V 50/60Hz | 30A | Dual NEMA L6-30P Plugs, 10'(3m), Bottom/Frt Cord | (24) IEC 60320/C13 (8) IEC 60320/C19 | 42.0 x 3.5 x 3.5 in. (1067 x 89 x 89 mm) |
| CW-32VDEAA15A1 CX-32VDEAA15A1* | 230V 50/60Hz | 16A | Dual IEC C20 Inlets, Bottom/Frt Entry | (24) IEC 60320/C13 (8) IEC 60320/C19 | 42.0 x 3.5 x 3.5 in. (1067 x 89 x 89 mm) |
| CW-32VDEKA15A1 CX-32VDEKA15A1* | 230V 50/60Hz | 32A | Dual IEC Blue 2P+G Plugs, 10'(3m), Bottom/Frt Cord | (24) IEC 60320/C13 (8) IEC 60320/C19 | 42.0 x 3.5 x 3.5 in. (1067 x 89 x 89 mm) |
| *Refers to Expansion Unit | |||||
| Power Cord Options | |||||
| PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10? > PTCORD-2 IEC 60320/C19 - Schuko 10? > PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10? > PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10? | |||||
| Additional Features and Specifications | |||||
| Standards > cTUVus ? UL 60950-1-2003 > CAN/CSA 22.2 No. 60950-1:2003 > TUVGS ? EN 60950-1:2001 > FCC Class A, Part 15 > CE > EMC-EN 55022 Class A, EN 55024 Communications > 10/100 BaseT Ethernet > HTTP/HTTPS > SSLv3/TLSv1 > SNMPv2 > SSHv2 > Telnet > LDAPv3/LDAPS > TACACS+ > RADIUS > RS-232 (Serial) Branch Circuit Protection > Compliant to UL 60950-1 Accessories > Temperature & Humidity Probe - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m) - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and 1 water sensor port | |||||
Inpidual or group outlet remote power control to cycle power and reboot any selected server(s) or other network device(s). Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each Sentry Cabinet PDU and rectify locked-up network devices. Assign outlets to a group for control of dual-power supply servers and other gear with a single command. Create an unlimited number of groups with any combination of outlets associated to each group. Reduce Mean Time to Repair (MTTR) a failing server by controlling inpidual power outlet receptacles to reboot any selected server or other device.
HTTP/HTTPs Web Configuration & ControlUse the Sentry Web interface to configure each unit, including network settings, outlet naming & grouping, SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to control inpidual or group outlets and monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.
SNMP Management & Event NotificationThe Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information and control power for the inpidual outlets. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off).
Add a Second TowerConnect an Expansion Cabinet PDU to any Switched Cabinet PDU to control two power input circuits and manage outlets (inpidual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.
Zero U EnclosureA vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.
Secure Access - SSH or SSL ProtectionSecure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device. Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.
Integrated Temp/Humidity ProbesTwo (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.
Firmware Flash UpgradeableAccess new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.
Click here for the latest Firmware update.
The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be inpidually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on inpidual Sentry products.
Sentry LDAP support has been tested in the following environments:
- Microsoft Active Directory (MSAD)
- Novell eDirectory (eDir)
- Open LDAP
Inpidual input current monitoring ("Load Sense") provides real-time power measurement of the load in amps on each power inlet, accessible via firmware interface.
RS-232 ControlSerial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.
16 or 20 Amp Power Input Support
16 or 20-Amp Power Input Support - IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX).
30 or 32 Amp Power Input Support
30 or 32 Amp Power Input Support provides hard-wired 10' cord and appropriate L5-30 or L6-30 plug type.
Use the firmware interface (Web or serial) to edit inpidual outlet receptacles. Identify each receptacle with the device's serial number, IP address, asset allocation #, department or any other method to inpidually name outlets.