The Sentry POPS/PIPS CDU provides real-time monitoring at both the infeed (PIPS) and inpidual outlet (POPS) level. Innovative Red-Lock receptacles are compatible with all manufacturers server power cords. Combine Server Technology's monitoring capabilities with our universal receptacles for a truly flexible CDU that fits all data center requirements.
PIPS (Per Inlet Power Sensing) and POPS (Per Outlet Power Sensing) provide the following monitoring capabilities.
Current Load (A)
Voltage (V)
Power (W)
Apparent Power(VA)
Crest Factor and
Power Factor
Utilizing our grouping feature, power information is available per device (multiple outlets), groups of devices (applications), inpidual Cabinet CDU, cabinet, rows of cabinets or the whole Data Center Floor. Combine the Sentry POPS Switched Cabinet CDU with the Sentry Power Manager (SPM) software tool to cluster outlets and gain power usage information across multiple Cabinet CDU's inpidual IP address.
The Sentry Power Manager (SPM) provides power distribution unit power (kW and kW-h) monitoring and environmental monitoring across all Sentry CDU's within the network. Reboot a single or dual-power supply server with one command. Receive email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Only the Sentry Power Manager is capable of regulating all Sentry Cabinet PDU's across the network while providing power readings and management at an outlet level.
产品图片:
产品特点:
Sentry Cabinet PDU Specifications | |||||
Item # | Available Input Voltages | Rated Amperage | Available Input Cord | Outlets | Dimensions (L x W x D) |
CWG-24V2/VE (24xC13) with PIPS | |||||
CWG24RX-2AKA58C1 CXG24RX-2AKA58C1* | 208-240 V 50/60Hz | 20A | IEC C20 Inlet, Top Cord Entry | (18) IEC 60320/C13 (6) IEC 60320/C19 | 69.0 x 2.2 x 3.50 in. (1753 x 56 x 89 mm) |
CWG24RX-2CKA58C1 CXG24RX-2CKA58C1* | 208-240 V 50/60Hz | 30A | NEMA L6-30P Plug, 10' (3m), Top Cord Entry | (18) IEC 60320/C13 (6) IEC 60320/C19 | 69.0 x 2.2 x 3.50 in. (1753 x 56 x 89 mm) |
CWG24RX-EAKA58C1 CXG24RX-EAKA58C1* | 230V 50/60Hz | 16A | IEC C20 Inlet, Top Cord Entry | (18) IEC 60320/C13 (6) IEC 60320/C19 | 69.0 x 2.2 x 3.50 in. (1753 x 56 x 89 mm) |
CWG24RX-EPKA58C1 CXG24RX-EPKA58C1* | 230V 50/60Hz | 32A | IEC Blue 2P+G Plug, 10'(3m), Top Cord Entry | (18) IEC 60320/C13 (6) IEC 60320/C19 | 69.0 x 2.2 x 3.50 in. (1753 x 56 x 89 mm) |
* CXG refers to the Expansion Module | |||||
Power Cord Options | |||||
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10' (3m) > PTCORD-2 IEC 60320/C19 - Schuko 10' (3m) > PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A Blue (UK Commando) 10' (3m) > PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10' (3m) | |||||
Additional Features and Specifications | |||||
Standards > US & Canada (cTUVus Mark) to UL 60950-1: 2007 and CAN/CSA 22.2 No. 60950-1-07 > European Union (TUVGS Mark) to EN 60950-1: 2006+A11 > FCC Class A, Part 15 > EMC to EN 55022 Class A, CISPR 22 Class A > CE Communications > 10/100 BaseT Ethernet > HTTP/HTTPS > SSLv3/TLSv1 > SNMPv2/v3 > SSHv2 > Telnet > LDAPv3/LDAPS > TACACS+ > RADIUS > RS-232 (Serial) > IPv6 Branch Circuit Protection > Compliant to UL 60950-1 Accessories > Temperature & Humidity Probe - EMTH-1-1 Temperature & Humidity Probe, 10 ft (3 m) - EMCU-1-1B add 2 additional Temperature & Humidity ports, 4 contact-closure monitoring ports and 1 water sensor port |
Power monitoring and information per inpidual outlet/device. Information includes: Current Load (A), Voltage (V), Power (kW), Apparent Power (VA), Crest Factor and Power Factor per outlet. Using our grouping technology, using clustering power information is available per device, groups of devices (application), inpidual CDU or cabinet. kW and kW-hour power information that can be utilized for billing, power monitoring, trending and power reports.
Network Access and Per Outlet ControlInpidual or group outlet network access power control to cycle power and reboot any selected server(s) or other network device(s). Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each Sentry Cabinet PDU and rectify locked-up network devices. Reduce Mean Time to Repair (MTTR) a failing server by controlling inpidual power outlet receptacles to reboot any selected server or other device.
POPS units can also be controlled on an per outlet basis. Assign outlets to a group for control of dual-power supply servers and other gear with a single command. Create an unlimited number of groups with any combination of outlets associated to each group.
Power information generated can be used to calculate PUE and DCIE. These power ratings have been established by the Green Grid to gauge efficiency.
Control Conditions for Alarm NotificationConditions for SNMP traps can be regulated for Status, Changes, Load, Temperature and Humidity.
HTTP/HTTPs Web Configuration & ControlUse the Sentry Web interface to configure each unit, including network settings, outlet naming & grouping, SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to control inpidual or group outlets and monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.
SNMP Management & Event NotificationThe Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information and control power for the inpidual outlets. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide network access power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off).
Add a Second TowerConnect an Expansion Cabinet power distribution unit to any POPS Cabinet PDU to control two power input circuits and manage outlets (inpidual or groups) under 1 IP address - our exclusive strategy for managing dual power-supply servers.
Zero U EnclosureA vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.
Secure Access - SSH or SSL ProtectionSecure Shell (SSH), known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a network access device. Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.
Integrated Temp/Humidity ProbesTwo (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.
Firmware Flash UpgradeableAccess new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.
Click here for the latest Firmware update.
The sentry family of products supports Lightweight Directory Access Protocol (LDAP) Version 3 including LDAPS (LDAP over TSL/SSL). This support enable authentication with LDAP servers; user accounts do not need to be inpidually created locally on each Sentry device.
This allows administrators to pre-define and configure (in each Sentry product, and in the LDAP server) a set of necessary LDAP groups, and access rights for each. User's access rights can then be assigned or revoked simply by making the user a member of one or more pre-defined Sentry LDAP groups. User account can be added, deleted, or changed in the LDAP server without any changes on inpidual Sentry products.
Sentry LDAP support has been tested in the following environments:
- Microsoft Active Directory (MSAD)
- Novell eDirectory (eDir)
- Open LDAP
Inpidual input current monitoring ("Load Sense") provides real-time power measurement of the load in amps on each power inlet, accessible via firmware interface.
RS-232 ControlSerial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.
20 Amp Power Input Support16 or 20-Amp Power Input Support - IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX).
24-Character Outlet Receptacle NamesUse the firmware interface (Web or serial) to edit inpidual outlet receptacles. Identify each receptacle with the device's serial number, IP address, asset allocation #, department or any other method to inpidually name outlets.