产品特点:
·
四种测试顺序可供选择:W,I,W-I,I-W。 ·
可与7305接地阻抗测试器连结使用。 ·
内建5组程序内存。 ·
缓升及测试时间可达999.9秒。 ·
键盘锁定功能。 ·
内建PLC Remote可程序遥控界面。 ·
台湾华仪(Extech) 7162 实用型耐压/绝缘测试仪,咨询电话:0512-68111419/13814830096
技术规格:
型号 | 7162 | 交流耐压 | 额定输出 | 5KVAC/12mA | | 范围 | 解析度 | 误差 | 输出电压, KVAC | 0-5.00 | 0.01 | ±(2% of setting + 5V) | 输出频率 | 50Hz/60Hz ±100ppm, User Selection | 输出波形 | Sine Wave ,THD.<2% (Resistive Load), Crest Factor = 1.3 -
1.5 | 输出调节 | ± (1% of output + 5V), From no load to full load | 设置 | 交流电流上限, mA | 0.10 - 12.00 | 0.01 | ±(2% of setting + 2counts) | 交流电流下限, mA | 0.00 - 12.00 | 0.01 | ±(2% of setting + 2counts) | 上升时间, 秒 | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | 测试时间, 秒 | 0, 0.2 - 999.9 (0=continuous) | 0.1 | 电弧侦测 | 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity) | 直流耐压 (7160,7162
ONLY) | 额定输出 | 6KVDC/5mA | 输出电压, KVDC | 0 - 6.00 | 0.01 | ±(2% of setting + 5V) | 输出纹波 | <5%(6KV/5mA at Resistive Load) | 设置 | 交流电流上限, mA | 0.02 - 5.00 | 0.01 | ±(2% of setting + 2counts) | 交流电流下限, mA | 0.00 - 5.00 | 0.01 | ±(2% of setting + 2counts) | 上升时间, 秒 | 0.1 - 999.9 | 0.1 | ±(0.1% + 0.05sec) | 测试时间, 秒 | 0, 0.2 - 999.9 (0=continuous) | 0.1 | 电弧侦测 | 0, 1 - 9 ranges (0=OFF, 9 is the most sensitivity) | 放电时间 | < 200 msec | 绝缘电阻 (7152,7162
ONLY) | 额定输出 | 1KVDC/1000MΩ | 输出范围, KVDC | 0.10 - 1.00 | 0.01 | ±(2% of setting + 3V) | 设置 | 绝缘电阻上限 MΩ | 0, 1 - 1000 (0=OFF) | 1 | ±(3% of setting+2counts)at > 500VDC | 绝缘电阻下限 MΩ | 1 - 1000 | 1 | ±(7% of setting +2counts)at <500VDC | 延迟时间, 秒 | 0, 0.5 - 999.9 (0=continuous) | 0.1 | ±(0.1% + 0.05sec) | 测量 | 交流/直流电压, KV | 0 - 6.00 | 0.01 | ±(1.5% of reading + 1count) | 绝缘直流电压, KV | 0.10 - 1.00 | 0.01 | ±(1.5% of reading + 3V) | 交流电流, mA | 0.10 - 12.00 | 0.01 | ±(2% of reading + 2counts | 直流电流, mA | 0.02 - 5.00 | 0.01 | ±(2% of reading + 2counts | 缘缘电阻,MΩ | 1 - 1000(Auto Range) | 0.001 0.01 0.1 | ±(3% of reading+2counts)at > 500VDC ±(7% of reading
+2counts)at <500VDC | 一般规格 | 输出电压, AC | 115/230Vac±15%, 50/60Hz ± 5%, Fuse 3.15A Fast | PLC远程控制 | Input : Test , Reset Output : Pass , Fail ,
Processing | 内存 | 10 Sets Store/Recall of each Memory, 4 Test Mode Selectable
(W, I, W~I, I~ W Only 7152, 7162) | 显示屏 | 16×2 LCD with back light | 按键锁定 | To prevent unauthorized alteration of the test
Parameters | 校验 | Build-in software and external calibrated meters | 环境 | 0-40℃, 20-80%RH | 尺寸/净重 | 280mm(W)×89mm(H)×300mm(D) / 8.4Kg | 标配附件 | 电源线(10A) | ×1 | 保险丝 | ×3 | 高压测试线 1.5m (1101) | ×1 | 高压回路线 1.8m (1102) | ×1 |
|