Technical Data WK3-180/70
Test Chamber
Test chamber material stainless steel, 1.4301, surface III D polished
Material of test space floor 1.4404, matt surface
Test area dimensions height approx. 750 mm
width approx. 580 mm
width between
shelf supports approx. 540 mm
depth approx. 450 mm
Volume of test chamber approx. 190 l
Max. loading 130 kg
Max. loading of test chamber floor 50 kg distributed load
Max. load per shelf 30 kg distributed load
Max. load of shelf supports 80 kg
Exterior Housing
Material double-coated galvanised steel sheet
Dimensions of housing height approx. 1805 mm
width approx. 780 mm
depth approx. 1385 mm
Overall dimensions 1) height approx. 1805 mm
width approx. 875 mm
depth approx. 1545 mm
Finish two-coloured, solvent-free, powder coated
corpus grey-white (RAL 9002)
front violet-blue (RAL 5000)
Door hinged on the left, lockable, optimum contact pressure
Feet adjustable, vibration absorbing
1 The required clearances can be reduced by dismounting components
Installation Drawing
Stainless steel port included in basic design
R1: approx. 125 mm
L1: approx. 50 mm
R21 … further installation position right
L21 … further installation position left
D11 installation position in ceiling
1. Main switch panel
2. 8” colour touch panel
3. CONTROLPAD
4. Condensation drain
5. Power supply cable length approx. 3,5 m
6. Door without window
8. Cooling water supply1
9. Cooling water drain1
10. Water supply (demineralised, H2O)
13. Slotted port1
14. Compressed air connection 1
# Width between shelf supports
1 Option
Equipment
Shelf 1 pc., stainless steel
Stainless steel ports 1 pc. approx. 125 mm , right side wall
1 pc. approx. 50 mm , left side wall
each port incl.
1 silicone plug closed
1 slotted plug made of foamed silicone
Condensation protection condensation cooler for prevention of condensation formation on specimen
8” TFT colour touch display fixed to front bracket
CONTROLPAD integrated in door, for display of actual values and modification of operating state
Control and programming digital measuring and control system S!MPAC*
Interfaces 1 Ethernet interface (100/10 Megabit) for integration into network
1 USB interface for direct documentation of measured data via USB stick (USB stick not included in scope of supply) or as a printer interface
Safety temperature limiter factory-set
Specimen protection high/low temperature fuse according to
EN 60 519-2, with separate sensor, thermal safety class 2
High temperature protection of humidification device high temperature controller
Specimen switch-off potential-free contact
Software temperature limiter tmin/tmax
Digital I/O 4 digital outputs for control of customer-provided devices by means of potential-free contacts, load max. 24 V-DC, 0,5 A
4 digital inputs for feedback of customer provided devices, load max. 24 V-DC, approx. 30 mA
Performance Data
Performances for temperature tests
Maximum temperature +180 °C
Minimum temperature -72 °C, discontinuously2)
Temperature change rate
cooling according to IEC 60068-3-53) approx. 3,0 K/min., on average, measured in the air inlet
Temperature change rate
heating according to IEC 60068-3-53) approx. 4,0 K/min., on average, measured in the air inlet
Temperature change rate
linear between +85 °C to -40 °C approx. 1,0 K/min., measured in the air inlet
Temperature deviation, in time, in steady state, depending on the temperature ±0,1 K to ±0,5 K
Temperature homogeneity, in space, depending on the adjusted set point value³ ±0,5 K to ±1,5 K
Max. heat compensation 1500 W
Calibration values +23 °C and +80 °C
2) In case of continuous, long-term operation below +5 °C ice might form on the evaporator if outer humidity is allowed to enter the chamber, for instance, by open apertures, doors or if additional humidity is generated by specimens or others.
In these cases, the evaporator needs to be defrosted from time to time by heating up to +10 °C.
³) In the temperature range of minimum temperature to +150°C.