'
Electrical Specifications
DC Operating Parameters TA = -40℃ to 150℃, VDD = 4.0V to 30V (unless otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Supply Voltage VDD Operating 4.0 12 30 V
Supply Current IDD VDD = 12V 1.5 3.0 4.5 mA
Power-Up State POS VDD > VDD( min) H H H
Supply Current IDD VDD = 4.0V to 30V 1.0 -- 6.0 mA
Leakage Current ILEAK VOUT = 4.0V to 30V -- -- 10 uA
Output Current IOUT Operating -- -- 25 mA
Output Saturation Voltage VSAT VDD = 12V, IOUT = 25 mA -- -- 600 mV
Output Current Limit ILimit VDD = 12V 50 100 150 mA
Output Short Circuit Shutdown TFAULT Fault 10 20 uS
Clock Frequency Fclk Operating 400 500 600 KHz
Output Rise Time
Tr VDD=12V, R1 = 1.0K,
Cload=10pF
-- -- 400 nS
Output Fall Time
Tf VDD=12V R1 = 1.0K,
Cload=10pF
-- -- 400 nS
Bandwidth BW Operating -- -- 15 KHz
Thermal Resistance RTH Operating -- -- 200 ℃/Watt
'