【Mini 1U Single】P1S-2400V


400W

Server ,Workstation ,Storage System ,IPC ,Blade server
150x81.5x40.3(mm)
5.91x3.21x1.59(inch)
VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:5.5 / 2.5 AMPS MAXIMUM
AT ANY LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE /
30A MAX. FOR 230 VAC PER MODULE
Output VoltageTD | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+12V | 2 | 33 | ±5% | ±1% | 120mV |
+5VSB | 0.1 | 2.5 | ±5% | ±1% | 50mV |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 12MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:>80% AT 115VAC, 40%~100% MAX LOAD
* LEAKAGE CURRENT: 3.5MA. MAX. AT NOMINAL VOLTAGE 250VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~160% MAX
* OVER VOLTAGE PROTECTION: +12V→13~16V
* SHORT CIRCUIT PROTECTION: +12V, +5VSB
* SAFETY: MEET UL/CUL, TUV EN-60950, CB IEC 60950, CCC
* WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.