【Micro Redundant】R1V2-5275V4H
275W
Server ,Workstation ,Storage System
295x106x41.8(mm)
11.61x4.17x1.65(inch)
VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A(RMS)FOR 230VAC
4A(RMS)FOR 115VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE
70A MAX. FOR 230 VAC PER MODULE
Output VoltageTD | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 0 | 20 | ±5% | ±1% | 50mV |
+12V | 0.1 | 22 | ±5% | ±1% | 120mV |
-12V | 0 | 0.3 | ±5% | ±1% | 120mV |
+3.3V | 0 | 20 | ±5% | ±1% | 50mV |
+5VSB | 0.1 | 2.5 | ±5% | ±1% | 50mV |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:78%±2% TYPICAL,AT FULL LOAD 230VAC
* LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~170% MAX
* OVER VOLTAGE PROTECTION: +5V→5.6~6.5V, +3.3V→3.6~4.3V, +12V→13.2~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY: MEET UL60950, TUV EN-60950, CB IEC 60950
* WARNING METHOD: AUDIO ALARM (BUZZER SOUND, RESETABLE), FALUT LED, TTL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.