【2U Redundant】R2W-6500P
500W
Server ,Workstation ,Storage System ,IPC
300x101x84(mm)
11.81x3.98x3.31(inch)
VOLTAGE: 105 ~ 264 VAC FULL RANGE
Output VoltageTD | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
5V | 2 | 30 | ± 5% | ± 1% | 50mV |
12V | 2 | 32 | ± 5% | ± 1% | 120mV |
-5V | 0.05 | 0.7 | +5 ~ -10% | ± 1% | 120mV |
-12V | 0.05 | 0.7 | +5 ~ -10% | ± 1% | 120mV |
3.3V | 1 | 24 | ± 5% | ± 1% | 50mV |
+5VSB | 0.1 | 2 | + 6 ~ -5% | ± 1% | 50mV |
| | | | | |
| | | | | |
| | | | | |
REMARKS: *THE OUTPUT CURRENT OF 5V & 3.3V NOT EXCEED 43A *TOTAL OUTPUT POWER NOT EXCEED 500w *Active PFC (full range), MEET IEC-1000-3-2 CLASS D
*12V Max. Current : 32A
*TEMPERATURE RANGE : OPERATING 0℃ ~ 40℃, STORAGE –20℃ ~ 70℃
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
*DUAL EMI NOISE INLET FILTER: FCC CLASS B, CISPR22 CLASS B
*SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950
*HOT-SWAPPABLE / HOT-PLUGGABLE REDUNDANCY FUNCTION
*Use 48-pins industrial connectors
*Cooling: TWO 38x38x28 mm DC FANS (MODULE)
*AC Inlet in each module
*Serial ATA optional
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.