Round
ferrules
Dimension C
(Diameter) 2 mm dia. max. (after crimping)
Safety Precautions
Wiring Precautions
• Do not
perform wiring work, remove connectors, or connect connectors while power is
being supplied.
Electric shock or damage to the device may
result.
• Double-check
all wiring before turning ON the power supply.
• After
wiring, route the cable so that force is not applied directly to the connections.
Wires for Terminal Blocks
• Do not
damage the cores when stripping the insulation from them.
• Always twist
stranded wires together before connecting them.
• Do not
presolder wires. It may not be possible to connect them or remove them.
XW2R-P@@ type (Square/Round ferrule)
Note: @@ of ferrule model is for color (Ex:
YE = Yellow)
When an electric wire is connected directly
(J,E,P type)
Mounting Units to and Removing Units from
DIN Track
Precautions for Correct Use
Type of terminal Manufacturer Size Recommend
ferrule Recommend crimp tool
Square ferrule
Phoenix Contact
AWG24 AI0.25-8@@
CRIMFOX6
AWG22 AI0.34-8TQ
AWG20 AI0.5-10WH
AI0.5-8WH
AWG18 AI0.75-10GY
AI0.75-8GY
AWG16 AI1.5-10BK
AWG14 AI2.5-8BU
Weidmuller
AWG24 H0.25/12
PZ6 roto
AWG22 H0.34/12
AWG20 H0.5/14
AWG18 H0.75/14
AWG16 H1.5/14
AWG14 H2.5/15D
Round ferrule Nichifu AWG22-
AWG16 TGV TC-1.25-9T
NH11
NH32