The ultraviolet band including UVA (320nm-380nm), UVB band (280nm-320nm) and UVC band (200nm-280nm).
UVA wave band is mainly used for light curing, UV light exposure lithography, lithography, integrated circuit industry etc..
UVC band, also known as the short wave ultraviolet sterilization. What ultraviolet germicidal lamp issued is short ultraviolet band UVC.
LS125 multi probe UV radiometer, using digital probe, plug design, instrument judge probe model intelligently. At the same time can support a variety of UV test probe, currently supports the following 6 kinds of UV Probes:
No. | Probe | Spectral Response | Measuring Range | Test | Application | UV range |
1 | P254 | 230nm-280nm λp = 254nm | 0-200000 uW/cm2 | P:Test Power | for 254nm UV germicidal lamp measuring | UVC |
2 | P297 | 230nm-280nm | 0-200000 uW/cm2 | P:Test Power | suitable for measure UVB light source that peak wavelength at 297nm,308nm,313nm etc. | UVB |
3 | E365
| 320nm-400nm λp = 365nm
| 0-10W/cm2 0- 999999mJ/cm2 | E:Test Power and Energy | UV Curing for UV curing machine basic for high pressure mercury lamp light source | UVA |
4 | E395 | 340nm-420 nm | 0-20W/cm2 0- 999999mJ/cm2 | E:Test Power and Energy | UV Curing for UV curing machine basic for LED light source | UVV |
5 | P365L | 320nm-400nm λp = 365nm | 0-200000uW/cm2 | P:Test Power, small measuring range | General industry | UVA |
6 | P420L | 340nm-420nm λp = 395nm | 0-200000uW/cm2 | P:Test Power, small measuring range | General industry |
UVV |

LS125 multi probe UV Light Meter
LS125 multi probe UV Light Meter, using digital probe, plug in type design, instrument intelligent judgment probe type. LS125 support UVA probe and UVC probe.
A: Probe Parameter
1: P254 Probe
1) Response wavelength: 230nm-280nm; λp = 254nm
2) Measuring range:0 - 200000 uW/cm2
3) Resolution: 0.1 μW/cm2
4) Accuracy: ±10 %
5) Test Hole Diameter: Φ10
6) Probe Size: Diameter 46mm×Thickness 16.1mm
2:P297 Probe
1) Response wavelength: 280nm-320nm; suitable for measure UVB light source that peak wavelength at 297nm,308nm,313nm etc.
2) Measuring range:0 - 200000 uW/cm2
3) Resolution: 0.1 μW/cm2
4) Accuracy: ±10 %
5) Test Hole Diameter: Φ10
6) Probe Size: Diameter 46mm×Thickness 16.1mm
3: P365L Probe
1) Response wavelength:260nm-400nm; λp = 365nm
2) Measuring range:0-200000uW/cm2
3) Accuracy: ±10 %
4) Resolution: 0.1 uW/cm2
5) Test Hole Diameter:Φ10
6) Probe Size: Diameter 46mm×Thickness 12.2mm
4: P420L Probe
1) Response wavelength:340nm-420nm;λp = 395nm
2) Measuring range:0-200000uW /cm2
3) Accuracy: ±10 %
4) Resolution: 0.1 uW /cm2
5) Test Hole Diameter:Φ9.2
6) Probe Size: Diameter 46mm×Thickness 14.6mm
5: E365 Probe
1) Response wavelength:320nm-400nm; λp = 365nm
2) Power Measuring range:0 - 10000 mW/cm2
3) 
Energy Measuring range: 0 --- 999999mJ/cm2
4) Accuracy: ±10 %
5) Resolution: 0.1 mW/cm2
6) Test Hole Diameter:Φ9.2
7) Probe Size: Diameter 46mm×Thickness 14.6mm
6: E395 Probe
1) Response wavelength:340nm-420nm;λp = 395nm
2) Power Measuring range:0-20000mW/cm2
3) Energy Measuring range: 0 --- 999999mJ/cm2
4) Accuracy: ±10 %
5) Resolution: 0.1 mW/cm2
6) Test Hole Diameter:Φ9.2
7) Probe Size: Diameter 46mm×Thickness 14.6mm
B: LS125 Main Body Paremeter1. Instrument Weight:about 320g
2. Main Body Size:125mm × 72mm × 14.5mm (LXWXH)
3. Power supply: 2 AAA alkaline battery
4. Probe connection: push pull (SNAP)
C: Button Operation1.Parameter Setting
At off state, long press“
” ,enter setup mode
Chose whether automatic shutdown( AUTO OFF : ON/OFF) : Short press“SELECT”choice ON/OFF
Select ON,Instrument will automatically power off in 10 minutes if without any operation。
Select OFF, the instrument won’t automatically shutdown, needs manual shutdown。
Confirm setting: short press "HOLD" button, completed setting, instrument enter measuring mode.
2. On / off
Short press“
” button for on / off operation
3.“HOLD” Button
l After boot, enter the record query mode, short press "HOLD" button to enter the measurement mode.
l In the measurement mode, at the same time, show the maximum current value and measurement time. Short press the "hold" button, all the data on the LCD be maintained, also save the maximum value and the real value and the measuring time in history.
l In the "keep" state, short press:
1) If the back light goes out, light up the backlight.
2) if the backlight is lit, into the "measurement", the "Hold" logo disappear.。
In the measurement mode, long press the "hold" button, save maximum value, current value and measuring time in history, and removal the maximum value, current value and measurement time, start a new measurement.
4.“SELECT”Button
Record query button, query stored history data.
The data in the "HOLD" state, Automatically be stored to “history data keeping group".
Records can be stored for 9 sets data, the old record values more than 9 sets will be automatically deleted.
In the "records" state, long press "SELECT" to remove all records, value.
The recorded data won't be not be lost while power off.
D: Change ProbeProbe connect method is push pull (snap). 1: insert probe, holding a host and the probe end aviation plug tail, rotating air plug until the plug and seat direction, alignment hole socket can be insertion.
2: Pulled out the Probe, as shown below, Hold the main body in the left hand, pinch the aviation plug "plug the card buckle tightly with thumb and index finger of right hand, pull towards the direction of the probe, the probe will be pulled out.

1. Probe connect method is push pull (snap). Non rotating the instrument probe.
2. Detector receiving window facing the UV light source, Can get current test point of UV radiation power density, and at the same time, shows a maximum (Pmax), the current value (PRT) , energy (E) or measurement time (T).
3. There is a magnet on instrument probe’s back , can be adsorbed on the iron plate, convenient for fixation.
4. Please press “POWER”button for power off, while not in use.
5. Avoid contact with corrosive substances, away from high temperature and high humidity environment.
6. Please Power Off and put it in the special packing, safekeeping.
7. Calibrate Period: The proposed calibration period is one year.
8. The ultraviolet probe is very sensitive to humidity change , so the preservative environment is very important. Please be sure to put the probe preserved in low humidity environment while the instrument not in use for a long time, For example, keep the probe in dry plastic bag.
F: ServiceManufacturer:Shenzhen Linshang Technology Co. , Ltd.
Website: www.lsmeter.com
www.lstek.cn
Email: ls21@lstek.cn
Linksun2008@hotmail.com
Skype:LINKSUN2008
Mobile Tel:(+86)13670090036
Wechat & Whatsapp:(+86)13670090036