认证和批准
按压力设备导则的分类 (DGRL97/23/EC) 用于流体组1的气体和流体组 1的液体:符合第3章第 3节要求 (探测工程规程 )
防爆
• 本安 “i” PTB 99 ATEX 2122
- 适用证书 Ex II 1/2 G EEx ia/ib IIB/IIC T6
- 允许的环境温度 -40 ... +85 °C 温度等级 T4;
-40 ... +70 °C 温度等级 T5 ;
-40 ... +60 °C 温度等级 T6 ;
- 连接 对于符合标准的本安电路,最大值:
Ui
= 30 V, Ii
= 100 mA,
Pi
= 750 mW; Ri
= 300 Ω
FISCO电源:
Uo = 17.5 V, Io = 380 mA, Po = 5.32 W
线性安全栅:
Uo = 24 V, Io = 250 mA, Po = 1.2 W
- 有效内电感 /电容 L
i
= 0.4 mH, Ci
= 6 nF L
i
= 7 mH, Ci
= 1.1 nF
• 隔爆 “d” PTB 99 ATEX 1160
- 适用证书 Ex II 1/2 G EEx d IIC T4/T6
- 允许的环境温度 -40 ... +85 °C 温度等级 T4;
-40 ... +60 °C 温度等级 T6 ;
- 连接 连接到电路: UH = 10.5 ... 45 V DC 连接到电路: UH = 9 ... 32 V DC
• 粉尘防爆区 20 PTB 01 ATEX 2055
- 适用证书 Ex II 1 D IP65 T 120 °C
Ex II 1/2 D IP65 T 120 °C
- 允许的环境温度 -40 ... +85 °C
- 最大表面温度 120 °C
- 连接 对于符合标准的本安电路,最大值:
Ui
= 30 V, Ii
= 100 mA, Pi
= 750 mW, Ri
= 300 Ω
FISCO电源:
Uo = 17.5 V, Io = 380 mA, Po = 5.32 W
线性安全栅:
Uo = 24 V, Io = 250 mA, Po = 1.2 W
- 有效内电感 /电容 L i
= 0.4 mH, Ci
= 6 nF L i
= 7 mH, Ci
= 1.1 nF
• 粉尘防爆区 21/22 PTB 01 ATEX 2055
- 适用证书 Ex II 2 D IP65 T 120°C
SITRANS P, DS III 系列, 用于表压测量