金海豪电力是生产高压和超高压输变电线路用钢化玻璃绝缘子,输变电站用高压玻璃悬式绝缘子,电气化铁路用直流玻璃绝缘子等产品的专业公司。
盘形悬式玻璃绝缘子LXY1-70,LXP1-70,FC70/146,LXY-100,LXP-100,FC100/146,LXY-120,LXP-120,FC120/146,LXY-160、LXP-160、FC160/170,LXY3-160,LXP3-160,FC160/155,LXY4-160,LXP4-160,FC160/146,U210B/170,LXY2-210,LXY3-210,LXP-210,LXP2-210,LXP3-210,FC210/170,U240B/170,LXY-240,LXY1-240,LXY2-240,LXP1-240,LXP2-240,FC240/170,U300B/195,LXY-300,LXY3-300,LXP-300,LXP3-300,FC300/195,U420B/205,LXY-420,LXP-420,FC420/205,U550B/240,LXY-550,LXP-550,FC550/240。防污型盘形悬式玻璃绝缘子LXHY4-70,LXHP4-70,FC70P/146,LXHY5-70,LXHP5-70,LXHY6-70,LXHP6-70,LXHY4-100,LXHP4-100,FC100P/146,LXHY3-100,LXHP3-100,LXHY6-100,LXHP6-100,LXHY4-120,LXHP4-120,FC120P/146,LXHY3-120,LXHP3-120,LXHY6-120,LXHP6-120,LXHY4-160,LXHP4-160,FC160P/155,FC160P/170,LXHY4-160,LXHP4-160,LXHY3-160,LXHP3-160,LXHY6-160,LXHP6-160,LXHY5-160。耐污玻璃绝缘子U210BP/155H, U210BP/170H,LXHY3-210,LXHY4-210,LXHP3-210,LXHP4-210,FC210P/155,FC210P/170,U240BP/170H,LXHY3-240,LXHY4-240,LXHP3-240,LXHP4-240,FC240P/170,U300BP/195H,LXHY-300,LXHY2-300,LXHY3-300,LXHP-300,LXHP2-300,LXHP3-300,FC300P/195。空气动力型钢化玻璃绝缘子U70BP/146M,LXAY-70,LXAP-70,U100BP/127M,LXAY-100,LXAP-100,U100BP/146M,U120BP/127M,LXAY1-120,LXAP1-120,U120BP/146M,LXAY-120,LXAP-120。
丰新电瓷型号:盘形悬式玻璃绝缘子U70B/146,U100B/146,U120B/146,U160B/170,U160B/155,U160B/146。防污型盘形悬式玻璃绝缘子U70BP/146H,U100BP/146H,U120BP/146H,U160BP/155H,U160BP/170H。
沧州金海豪电力绝缘子有限公司
CangZhouJinHaiHaoDianLi
销售Sal:王宁波
手机Mob:18233693185(同微信)13833772295 18632785836
电话Tel:86-0317-3866525
传真Fax:86-0317-3868525
网站Web:www.jueyuanzi.net
邮箱E-mail(QQ):885266961@qq.com
厂址Add:河北省沧州市河间城东开发区
技术参数表
绝缘子型号 | U70B/146 | U80B/146 | U100B/146 | U120B/146 | U160B/155 | U210B/170 | U240B/170 | U300B/195 | U420B/205 | U550B/240 |
公称直径D(mm) | 255 | 255 | 255 | 255 | 280 | 280 | 280 | 320 | 360 | 360 |
结构高度H(mm) | 146 | 146 | 146 | 146 | 155 | 170 | 170 | 195 | 205 | 240 |
公称爬电距离L(mm) | 320 | 320 | 320 | 320 | 400 | 400 | 400 | 485 | 550 | 620 |
连接标记(mm) | 16 | 16 | 16 | 16 | 20 | 20 | 24 | 24 | 28 | 32 |
额定机械破坏负荷(kN) | 70 | 80 | 100 | 120 | 160 | 210 | 240 | 300 | 420 | 550 |
逐个拉伸负荷(kN) | 35 | 40 | 50 | 60 | 80 | 105 | 120 | 150 | 210 | 275 |
工频干耐受电(kV) | 70 | 70 | 70 | 70 | 75 | 75 | 75 | 85 | 90 | 95 |
工频湿耐受电(kV) | 40 | 40 | 40 | 40 | 45 | 45 | 45 | 50 | 55 | 55 |
雷电冲击耐受电压(kV) | 100 | 100 | 100 | 100 | 110 | 110 | 110 | 130 | 140 | 145 |
冲击过电压击穿耐受电压(p.u.) | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 |
最小工频击穿耐受电压(kV) | 130 | 130 | 130 | 130 | 130 | 130 | 130 | 130 | 130 | 130 |
无线电干扰10kV;1MHz(µV) | ≤50 | ≤50 | ≤50 | ≤50 | ≤50 | ≤50 | ≤50 | ≤50 | ≤50 | ≤50 |
可见电晕电压 脚帽(kV) | 18/22 | 18/22 | 18/22 | 18/22 | 18/22 | 18/22 | 18/22 | 18/22 | 18/22 | 18/22 |
工频电弧试验 | 0.12s/20kA | 0.12s/20kA | 0.12s/20kA | 0.12s/20kA | 0.12s/20kA | 0.12s/20kA | 0.12s/20kA | 0.12s/20kA | 0.12s/20kA | 0.12s/20kA |
绝缘子单片重(kg) | 3.6 | 3.6 | 4.0 | 4.0 | 6.5 | 7.2 | 7.5 | 10.6 | 14.6 | 19.1 |