一:瑞典TA静态平衡阀STAD 不锈钢平衡阀瑞典TA静态平衡阀STAD,STADA,STAD-C,STA-DR ,STA,STAM,STS静态平衡阀
用途:供热与制冷系统(甘醇/盐水);饮用水系统;(冷水/热水);海水(冷水)
功能: 压力等级:PN20
温度:最高工作温度: STAD, STADA, STA-DR, STA, STAM, STS:120°C
(如需更高的工作温度,最高150°C,请与TA公司联系)STAD-C:150°C(当温度高于120°C时,请卸下手轮)
最低工作温度:-20°C
材质:各阀均全部采用AMETAL®合金制成 阀座密封:阀杆带EPDM材料O型圈轴的密封:EPDM制O型圈
手轮:聚酰胺材料
AMETAL®是TA专利的防脱锌合金
标示:阀体:PN20/150,公制规格(DN)及英制规格(英寸); 手轮:阀型及公制规格(DN)
二:瑞典TA静态平衡阀STAD 不锈钢平衡阀瑞典TA STAF STAF-SG,STAG STAF-R静态平衡阀
应用范围:STAF,STAF-SG,STAG:供热节制冷系统
STAF-R:用于生活水系统,热水系统,冷水系统,冷海谁(低于30℃)及冷却塔循环水系统
最大工作压力:STAF STAF-SG/STAG STAF-R 16bar 25bar 16bar
额定压力:STAF STAF-SG/STAG STAF-R PN16 PN25 PN16
温度:最高工作温度:120℃如需要更高的工作温度(150℃),请与TA公司联系 最低工作温度:STAF:-10℃ STAF-SG,STAG,STAF-R,-20℃
材料:阀体:STAF:铸铁EN-GJL-250(GG250)
STAF-SG/STAG:球墨铸铁EN-GJS-400-15 STAF-R:青铜CUSn5Pb 5Zn5
DN20-20-50:阀帽,阀芯,阀轴为AMETAL
DN200-300:阀帽为球墨铸铁,阀芯为硅黄铜,阀轴为AMETAL
DN350-400:阀帽为球墨铸铁,阀芯为硅黄铜,CuZn16Si4-C
(EN1982)或黄铜CuZn35PbZAI-C-GS(EN1982),阀轴为AMETAL
阀座密封:阀芯带有EPDM圈阀盖螺栓:镀铬钢制
数字手轮:DN 2-150的阀门配以红色聚酰胺塑料手轮,DN 200-400的阀门配以红色铝制手轮
AMETAL®是TA专利的脱锌耐蚀TA合金
三:瑞典TA静态平衡阀STAD 不锈钢平衡阀瑞典TA动态流量平衡阀
自动平衡的益处
在任何暖通空调(HVAC)系统中,主机和末端设备都是核心部件,因此对这些设备进行正确地选型,并保证其获得需要的流量显得十分关键。没有正确的流量,就无法实现设备装机功率,从而就会大大降低系统的运行效率,以至于无法达到舒适度要求。
采用自动平衡设计,可以确保系统实现精确的动态水力平衡。这就意味着,当系统工况发生变化时,各设备仍然能够在设计流量下运行。
四:瑞典TA固定流量测试孔板
概述:
该产品为图片式的测量孔板,安装于BS4504(EN1092,ISO 7005)的法兰之间。
型号52 176和52 276带有加长的自密封测量端口。
型号52 576带有加长的双功能PT100测量端口。
该测量孔板符合BS 1042:1.1:1992(ISO 5167 - 1:1991)章节的标准。
该流量测试计算法符合BS 1042:1.4:1992章节标准。
技术数据 应用范围:供热及制冷系统,供水系统功能:测量
压力等级: PN 16(DN 20-900) PN 25(DN 65-300) PN 40(DN 65-300)温度:最高工作温度:120℃ 最低工作温度:-10℃
材质:固定孔板:不锈钢(BS 970316/S16) 测量端口:AMETAL
AMETAL 是TA专利的防脱锌铜合金
标识:TA,MDFO,DN,PN,Charge No,flow direction arrow. DN 20-150(PN 16):BS 7350
自动平衡还有其它优点,例如:节约输配能耗、降低水泵扬程以及减少系统平衡调试工作量等,这些优点将在后面的部分进行详细阐述。
五:瑞典TA丝口压差控制阀STAP
应用范围:供应及制冷系统
功能:压差控制 可设定△P 具有测点 关断 泄水(配件)
压力等级:PN16 最大压差(△Pv):250kpa
温度:最高工作温度:120°C 最低工作温度:-20°C
设定范围:DN 15-25:10-60kpa DN 32-50:20-80kpaSTAP DN 32-40 低压差控制范围:10-40 kPa
材料:阀体: AMETAL 阀盖:AMETAL O 型圈:EDPM橡胶 阀座密封:带EPDM O型圈的阀杆
膜片:EPDM橡胶 弹簧:不锈钢 手轮:聚酰胺
AMETAL 是TA专利的防脱锌合金
标识:阀体:PN 16/150,口径(英寸) 阀盖:STAP, △pL 10-60或20-80
六:瑞典TA法兰压差控制阀STAP
应用范围:供应及制冷系统
功能:压差控制 可设定△p 具有测点 关断
压力等级(△pv): PN16 最大压差: 350 kPa
温度:最高工作温度:80°C 最低工作温度:-10°C
设定范围: 20-80 kPa或40-160 kPa。
材料:阀体: 铸铁EN-GJL-250(GG25) 阀盖: AMETAL O型圈:EDPM橡胶
阀座密封:带EPDM O型圈的阀杆 膜片:加强型EPDM橡胶 弹簧:不锈钢 手轮:聚酰胺
(AMETAL 是TA专利的防脱锌合金)
表面处理:阀体:环氧树脂喷涂
标识:阀体:TA,PN 16,DN,CE,250 Cl流向箭头以及铸造日期(年月日)阀装置及手轮:标有STAP,DN,△pL 20-80或40-160 kPa以及条形码
面对面尺寸:ISO 5752系列1,BS 2080
法兰:ISO 7005-2
七:瑞典TA丝口、法兰压差控制阀DA516
应用:变流量的供暖系统和供冷系统
功能:负荷侧的压差控制
压力级:DN 15 -125:PN 25如有要求,DN 65-125:PN 16)
最大压差:1600 kPa=16 bar
温度:最高工作温度:140℃ 最低工作温度:-10℃
设定的范围:△P可在5-30kPa,10-60kPa,10-100kPa或者60-150kPa的范围内进行调节。
出厂预设定:最大值(分别为30、60,100或150kPa)
媒介:水和中性流体,水乙二醇混合物
材料:阀体:球墨铸铁 EN-GJS-400-18LT薄膜和垫圈:EPDM调节环:DN 15-50Ryton 塑料,DN 65-125 R St 37-2钢
表面处理:电泳涂装
标识:TA-Regulator,DN,PN,GGG 40.3,Kvs△P以及流向箭头
法兰盘:DN 15-50:符合EN-1092-2:1997,第16类 DN 65-125:符合EN-1092-2:1997。第21类
八:瑞典TA压差控制阀DA50
应用:供暖系统和供冷系统 区域供冷/热二级站的一次侧
介质:水和中性液体, 水乙二醇混合物
功能:负荷侧的压差控制
表面处理:面漆
压力级:DN 32-125:PN 16(如有要求,可提供PN25) DN 150-200:PN 25
标识:TA-Regulator, DN,PN以及流向箭头
法兰盘:DN 32-50:符合EN-1092-2:1997,第16类 最大差压 DN 65-200:符合EN-1092-2:1997,第21类
最大差压:1600 kPa=16 bar
温度:最高工作温度:150℃ 最低工作温度:-10℃
设定的范围:△P可在10-60 kPa的范围内进行调节。(如有要求,调节的范围可以是50-150和120-250 kPa。)
出厂预设定:10 kPa (50 kPa和120 kPa对应以上不同范围)
材料 阀体:PN 16:铸铁 EN-GJL-250 PN25:球墨铸铁 EN-GJS-400-18LT 驱动器缸体:球墨铸铁 EN-GJS-400-18L 薄膜: EPDM 阀心: 有EPDM塞的不锈钢 阀座:不锈钢
九:瑞典TA电动平衡二通阀TBV-C
技术数据 应用范围:供热与制冷
功能:控制/平衡/预设定/测量/关断
压力等级: PN 16
温度:最高工作温度:120℃ 最低工作温度:-20℃
材质:阀体:AMETAL® 阀座密封:EPDM阀盘 阀杆密封:EPDM O-型圈阀芯:AMETAL®、PPS(聚丙烯)
复位弹簧:不锈钢 阀杆:含聚四氟乙烯(特富龙)AMETAL®
AMETAL® 是TA专利的防脱锌铜合金
标识:阀体:TA,PN 16/150,DN,英制尺寸以及液体 流向指示箭头 测量棒上的型号标识
十:瑞典TA动态平衡电动调节阀(三合一) KT512 KTH512 KTM512
应用范围:变流量供冷系统及供热系统
功能:
稳定内置控制阀的压降,流量调节,静态平衡
KT512:开关控制
KTH512:线性控制
KTM512:等百分比控制
额定压力:2.5MPa 最大工作压差差:1.6MPa
工作温度:-10 - 140℃
介质:水、中性液体、乙二醇水溶液
表面处理:电泳喷涂
十一:瑞典TA-CBI测量设备
Technical description
TA-CBI is a computer programmed balancing instrument. It consists of an electronic differential pressure gauge and a
micro computer which has been programmed with the TA
valve characteristics which makes possible a direct reading of flow and differential pressures.
The TA-CBI has two main components:
- An instrument which contains a micro computer, input touch
pad, LCD display and re-chargeable NiMh batteries.
- A sensor unit which contains a piezoresistive pressure
sensor, one measurement valve and connections.
The measurement valve has a safety function which protects
the sensor from too high differential pressures.
Measurement range:
Total pressure: max 2 500 kPa.
Differential pressure: -9 to 200 kPa.
Flow: During flow measurements the pressure range is 0.5 to200 kPa.
Temperature: -20 to 120°C
Temperature liquid medium:-20 to 120°C
Measurement deviation:Differential pressure: The greater of ±1% of displayed value or±0.2 kPa
Flow: As for differential pressure + valve deviation.
Temperature: <0.2°C + sensor deviation.
Effective operating time:
8 to 10 h between charges depending upon application.
Ambient temperature for the instrument:
0 to 40°C (during operation)
5 to 40°C (charging)
-20* to 60°C (storage)
*) Do not leave water in the sensor when there is a risk of
freezing.
十二:瑞典TA地板辐射采暖系统分水器
概要:该地板辐射采暖分水器的尺寸为G1,并且成对供应,即供水侧和回水侧。同时提供2、3或4个G3/4分支接头。
每个分水器的末端配备了排气及泄水阀,以及一个旁通装置。对于直型或角型的,可以使用关闭阀。球阀、分水器和末端单元的接头用O形环密封。
技术说明应用:地板辐射采暖系统
功能:分水器是地板辐射采暖系统的重要组成部分:实际的地板采暖盘管从分水器开始,并返回分水器。分水器回水阀体带有平衡作用,可以利用4mm内六角扳手设置这些阀门来平衡每个回路之间的流量和压降。系统中地板供暖盘管的总数不得超过12。
瑞典TA中国介绍
TA身为IMI集团室内环境事业部(IMI Indoor Climate)之重要成员,在集团的支持下,已经在16个国家设有营销公司和其他50个国家拥有分销商和代理。以下是TA所属集团公司的介绍:
身居室内,细心的您是否曾发现这样的问题:为什么远离锅炉的房间经常太冷,而靠近锅炉的房间却经常太热呢? 平衡阀的概念就此产生 1897年,TA公司就开始在距离哥德堡100公里的Ljung小镇制造用于供热和冷却系统的阀门。1962年, Ragner Garfvee和TA公司获得了世界上第一个平衡阀专利。在随后的40多年中,平衡阀被广泛应用于供热系统以及空调系统等,TA也逐步形成了一整套从设计到服务的 “全面平衡” 概念和解决方案,为全球10万余个项目的水系统实现平衡并有效节省能源消耗。TA以卓越的技术能力、丰富的项目经验,为全世界建筑系统提供高效节能的全面水力平衡控制解决方案。 | |
企业社会责任 我们坚信可持续发展的业务 我们立意成为世界上最关注客户、最专业和最具创新精神的水力平衡解决方案提供者。我们 致力于了解客户需求,利用丰富经验和知识,以具竞争力的价格为客户提供创新构思和可靠 的解决方案。 我们坚信,只有负责任的公司才能建立持续发展的业务,绝不会损害环境而危及子孙后代。 我们关心环境、能效、健康与安全,我们讲究道德,守法经营,和大家共同建立一个和谐、 可持续发展的社会。 五个首要问题 我们的使命是为客户创造能够达到最佳设计要求的室内环境,这意味着既能节省能源又能节 约成本无论在家还是工作,人们都应当拥有一个舒适的室内环境。企业社会责任使我们更加 坚持我们的使命,为子孙后代着想,为创建一个可持续发展的社会而不断努力。我们的企业 社会责任政策包含五大方面,使公司和社会都能受惠。 最小的环境影响 室内环境集团在减少生产业务对环境的影响方面取得重大成果。公司内部员工均接受公司环 保计划方面的培训。 保计划方面的培训。 从设计阶段开始,我们就选择对环境影响尽可能小的材料和制造方法。我们供应对环境无害 的产品,使用寿命结束之后还可回收利用。我们确保在制造及生产过程中不会将任何有害物 质排放入水系,并尽力将二氧化碳的排放保持在最低水平。 安全而舒适的工作场所 室内环境集团采取预防措施来降低健康和安全方面的风险。我们绝不降低我们的员工健康及 安全标准。 安全标准。 室内环境集团保证工作场所的安全。我们提供这方面的培训和咨询,确保一旦发生意外立即 立案跟踪调查。我们主动采取措施,鼓励员工在出现事故时参与事故控制计划及康复计划。 我们尽量降低能耗 我们帮助客户提高能效,也确保自己保持高能效。室内环境集团的各个工厂一贯保持降低能 源销售比的长期传统,这给公司在经济和环保方面都带来积极的影响。 我们不断寻求长期及短期的商机,以开发有助于改善能源利用的新产品。 遵守商业道德理所当然 室内环境集团遵循并执行各项法律及合同要求,以最高的道德标准来要求自己、伙伴和供应商。 我们确保在与他人做生意的时候双方以同样的方式来互相对待。 我们获得客户、供应商和交货伙伴的信赖,因为我们在合同期的各个阶段保持与各方联络的渠 道畅通无阻,确保每个变化在早期就能通知各方。 我们的专业知识使客户和公司双方受益 通过持续发展我们的专业知识,我们力争在本行业所有领域内独占鳌头,其中包括产品开发、 产品制造、设计咨询,还有客户培训及技术支持等等领域。 我们也在员工发展方面大力投资,以提高他们的表现和能力。我们提供全面的内部和外部培训 计划,通过举办讲座及研讨会来为客户、供应商和员工提供培训。 | |
瑞典TA全面的水力平衡阀:
HVAC系统效率的高低直接决定了系统的运行能耗,提高系统效率是降低能耗的主要手段。全面水力平衡技术是TA发明的,该技术已经在欧洲10万多个项目中获得了应用,取得了良好的节能舒适效果。 中央空调系统在实现设定温度的过程中除了受到外部负荷变化的影响外,还有系统内控制回路之间的干扰以及系统先天水力失调的影响。这些内部的影响如果不进行修正和补偿就会造成BMS控制系统失去功效。动态的内部干扰随着系统压差的变化而产生,并且压差变化越大干扰就越大。水力平衡技术是唯一可以对这种“先天失调”以及动态交互性进行修正和补偿的技术手段。将平衡技术与传统BMS控制技术有效地结合起来才能实现系统的真正控制。 TA进入中国市场以来,不断为客户提供新的水力平衡技术与产品,TA公司针对中国市场特点推出水系统全面控制和解决方案,它的主要特点是采用全面平衡与控制的结合技术,提高整个系统的运行效率。有了这些强有力的工具,水系统的平衡变得轻而易举了。 | ||
辅助设计省时省力:实现精确的水力计算,十万余项目经验支持。 |