CyberPower SM30KPMX for data centers, public transportation, infrastructure and emergency system and long-term reliable backup power supply for the equipment. Modular UPS (three-phase) series have weaver redundancy function, is suitable for the need of high capacity, high reliability and prolong the time application situation, such as professional server room, data center, industrial factories and power plants and other important equipment. Digital signal processing and control combined with IGBT technology and wisdom, can be in energy saving mode to reduce total harmonic distortion (THDi), reach up to 98% of the power efficiency, become the industry the highest efficiency of the UPS. Its high efficiency relatively low thermal energy and power consumption, and therefore to reduce operating costs and carbon emissions. Has the character of extensible modular UPS (three-phase), existing backup power system total load capacity can be increased to 400 kva. When each independent power supply module for parallel architecture, UPS can be equally Shared back-end load power consumption, so as to realize the power of the N + 1 redundancy. A failure occurs in a single power supply module, the load will be automatically assigned to other modules, in order to avoid the risk of a single point of failure. Each power module with the function of hot plug, the power supply and maintenance convenient extension system, does not need to interrupt operation of electric power load, thus improving the reliability of the system.
CyberPower SM30KPMX 能为数据中心、大众运输、基础设施以及应急系统等设备提供长效可靠的后备电力。模块化 UPS(三相)系列具有并机冗余功能,适用于需要高容量、高可靠性和延长执行时间的应用情境如专业服务器机房、数据中心、工业工厂和发电厂等重要设备。 结合IGBT技术和智慧数位讯号处理控制,可在节能模式下降低总谐波失真(THDi),达到高达98%的功率效率,成为业界最高效能的UPS。其高效率相对产生较低的热能与功耗,因而也减低运营成本以及碳排放。 模块化UPS(三相)具有可扩展的特性,可将现有备用电源系统的总负载容量提高至400Kva。当每个独立的电源模块用于并联架构时,UPS可平均共享后端负载消耗的功率,从而实现 N + 1 的电源冗余。在单一电源模块发生故障时,负载将自动分配到其它模块中,以避免单点故障的风险。每个电源模块具热插拔功能,以方便扩展电源和维护系统,不需中断运行中的电力负载,因而提高系统的可靠性。
产品特性
常见应用
一般
相三相模块UPS
UPS 原理在线式双转换
节能技术ECO 节能模式,输出效能可达 98%
正常模式效率 ( % )95%
电池模式效率 ( % )95%
主动式 PFC 兼容式设计是
输入
输入电压 ( 交流电压 )相间((L-G): 380 ~ 415 Vac 线到中性点(L-N): 220 ~ 240 Vac
输入电压范围 ( 交流电压 )相间((L-G): 228 ~ 478 Vac 线到中性点(L-N): 132 ~ 276 Vac
可调电压范围 ( 交流电压 )相间((L-G): 380 ~ 435 Vac 线到中性点(L-N): 220 ~ 250 Vac
输入频率 ( Hz )60 ± 3 50 ± 3
额定电流输入 ( 电流(安培) )41
输入功率因子0.99
输出
容量(VA)30000
容量(瓦)27000
电池输出波形纯正弦波
输出电压设定可设定
输出频率设定可设定
输出电压 ( 交流电压 )相间((L-G): 380 ~ 415 Vac 线到中性点(L-N): 220 ~ 240 Vac
输出电压公差 ( % )1.5 %
功率因素0.9
省电 (ECO) 模式电压容许范围± 10 %
过载保护内部限流 , 保险丝
过载保护 (市电模式)负载105~110%可维持60分钟,负载110~125%可维持10分钟,负载125~150%可维持1分钟,负载>150%即刻跳至过载保护
过载保护 (电池模式)负载105~110%可维持60分钟,负载110~125%可维持10分钟,负载125~150%可维持1分钟,负载>150%即刻跳至过载保护
过载保护 (旁路模式)负载110~125%可维持5分钟,负载125~150%可维持1分钟,负载150~400%可维持1秒,负载>400%即刻跳至过载保护
波峰因子3 : 1
谐波失真 (线性负载)THD<1%
谐波失真 (非线性负载)THD<5.5%
内部旁路自动旁路 , 手动旁路
维修旁路是
标准转换时间 ( 毫秒 )0
电池
电池充电功率 ( % )20 % x Power
设定电池充电电流可设定
智能电池管理 (SBM)是
雷击与突波抑制
电磁波干扰保护是
通讯管理
LED 指示灯是
外观
外型架构机架
外壳材质金属
颜色黑
机架式耳片是
尺寸 - 电力模块
尺寸 (WxHxD) (mm.)460 x 134 x 790
重量 (kg.)34
运送尺寸大小
尺寸 (WxHxD) (mm.)625 x 985 x 965
重量 (kg.)130
环境
操作温度(°F)32 ~ 104
操作温度(°C)0 ~ 40
操作湿度 ( % )0 ~ 95
适用海拔高度范围 ( 英尺/米 )≤1000,每100米负载降低1%从海拔1000~2000米
贮藏温度 (华氏)-40 ~ 158
贮藏温度 (摄氏)-40 ~ 70
贮藏湿度 (非冷凝) ( % )0 ~ 95
风扇产生噪音值 (1.5M) ( dBA )55
认证
认证CE , IEC62040-1 , IEC62040-2