赖晚兵 13661709198微信同号 qq:2851001710
General specifications Signal type Analog input Functional safety related parameters Safety Integrity Level (SIL) SIL 2 Supply Connection Power Rail or terminals 9+, 10- Rated voltage 19 ... 30 V DC Ripple within the supply tolerance Rated current < 20 mA Power consumption 0.35 W (24 V and 1 mA sense current) Input Connection side field side Connection terminals 1, 2, 3, 4 Line fault detection yes , at Pt100 Lead resistance ≤ 10 % of resistance value Transmission range 0 ... 10 mA Available voltage 9 V Line fault detection 8 nA Output Connection side control side Connection terminals 5-, 7-, 6+, 8+ Current 0 ... 10 mA Available voltage 0 ... 4.2 V Fault signal 400 Ω, depending on lead disconnected (measuring current ≤ 1 mA) 400 Ω, terminal 3 lead disconnected in 2-/4-wire (measuring current ≤ 0.3 mA) Transfer characteristics Accuracy 0.1 % Deviation 4-wire
Im ≥ 1 mA: ±0.1 % of Rm or ± 0.1 Ω (the larger value is applicable)
Im < 1 mA: accuracy reduces in proportion to Im.
e. g. Im = 0.1 mA: ± 1 % of Rm or 1 Ω (the larger value is applicable).
3-wire
Im ≥ 1 mA: (±0.1 % - 0.1 Ω Offset) or ± 0.2 Ω (the larger value is applicable)
Im < 1 mA: accuracy reduces in proportion to Im.
e. g. Im = 0.1 mA: (±1 % - 0.1 Ω Offset) or ± 1.1 Ω (the larger value is applicable)Influence of ambient temperature Im ≥ 1 mA, Rm ≥ 100 Ω : 0.01 %/K in the range -20 ... +60 °C (253 ... 333 K)
Im < 1 mA or Rm < 100 Ω: temperature stability reduces in proportion to Im or RmRise time signal response time ≤ 2 ms (10 ... 90 %)
response to application of Im: Rm > 50 Ω and Im < 5mA: < 5ms
response to application of Im: Rm > 30 Ω and Im < 5mA: < 10ms
response to application of Im: Rm > 18 Ω and Im < 5mA: < 20msGalvanic isolation Input/Output reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff Input/power supply reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff Output/power supply functional insulation, rated insulation voltage 50 V AC Indicators/settings Display elements LED Control elements DIP-switch Configuration via DIP switches Labeling space for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 (industrial locations) Conformity Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529:2001 Protection against electrical shock UL 61010-1 Ambient conditions Ambient temperature -20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protection IP20 Connection screw terminals Mass approx. 100 g Dimensions 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001 Data for application in connection with hazardous areas EU-type examination certificate BASEEFA 10 ATEX 0061 Marking II (1)G [Ex ia Ga] IIC
II (1)D [Ex ia Da] IIIC
I (M1) [Ex ia Ma] IInput [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Voltage 12.4 V Current 17.4 mA Power 54 mW Supply Maximum safe voltage 253 V (Attention! The rated voltage can be lower.) Output Maximum safe voltage 253 V (Attention! The rated voltage can be lower.) Certificate BASEEFA 10 ATEX 0062X Marking II 3G Ex ec IIC T4 Gc Galvanic isolation Input/Output safe electrical isolation acc. to IEC/EN 60079-11:2012, voltage peak value 375 V Input/power supply safe electrical isolation acc. to IEC/EN 60079-11:2012, voltage peak value 375 V Directive conformity Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 International approvals FM approval Control drawing 116-0129 (cFMus) UL approval Control drawing 116-0332 (cULus) IECEx approval IECEx BAS 10.0024
IECEx BAS 10.0025XApproved for [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I , Ex ec IIC T4 Gc General information Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.