Phase meter - phase angle meter - phase measurement
* 0.02º phase accuracy and 0.001º resolution
* Fully isolated inputs
* 700 kHz frequency range
* Accurate with noisy, distorted and non-sinusoidal signals
* Fully autoranging and easy to use
* Voltage or current inputs
* High common-mode noise rejection
* 500 Vpk input voltage capability
* 1mV sensitivity
* 10000:1 input ratio / imbalance capability
* IEEE-488, RS232 and printer interfaces
* Traceable to international standards
A phase meter not influenced by input noise and distortion
The SD1000 phase meter offers superb accuracy with a wide range of signal conditions. Conventional phase meters are easily upset when small levels of noise and distortion are present - the result is often unstable and incorrect phase readings. The SD1000 overcomes this by using Discrete Fourier Analysis (DFT), this process rejects any noise and distortion without the need for tracking filters.
Isolated Inputs
The SD1000 phase meter has totally isolated (floating) measurement inputs, allowing the user to connect anywhere in the circuit. This is very useful when the circuit under test does not have common grounds, eliminating accidental grounding and ground-loop currents. The user may choose voltage-voltage phase measurement, voltage to current phase measurement or current to current phase measurement, ideal for phase protection, power meters, energy meters and current transformer calibration
World-wide Traceability
All measurements made with the SD1000 phase meter are traceable to National and International standards through the measurement standards of Powertek. The SD1000 is supplied with a certificate of conformance necessary for quality assurance standards such as ISO9001. A UKAS (independent measurement certification organisation) certificate is available.
SD1000 phase meter specifications
Phase Range ± 180.000º or 0.00º to +360.00º
Accuracy (23º ± 5ºC; 1-year cal interval) 0.1Hz to 99Hz ± 0.02º ± 1 digit
100Hz to 999Hz ± 0.03º ± 0.005º /kHz ± 1 digit
1kHz to 99kHz ± 0.04º ± 0.005º /kHz ± 1 digit
100kHz to 700kHz ± 0.25º ± 0.003º /kHz ± 1 digit
Resolution 0.001º
Repeatability 0.005º ( ±0.003º via interfaces)
Frequency Range 0.1Hz to 700 kHz
Accuracy ±0.1% (23º ± 5º)
Inputs Voltage Range
Current ranges using Options 02F/B
All voltage and current input combinations are possible 1mV rms to 350V rms (500V pk)
20mA - 2Arms range Opt. 02F/B 1R00 5Hz - 20kHz
1.0Arms to 20Arms range Opt. 02F/B 0R01 5Hz - 20kHz
Bandwidth 0.01Hz to 700kHz
Isolation (inputs to ground) 2000V
Impedance 2 Mohm and 10pF
Environment Temperature Operating 0ºC to + 50ºC
Storage -40ºC to +70ºC
Humidity (non-condensing) 10% to 90% RH
Dielectric Strength Inputs to case or AC line input 2kV AC 50/60Hz 1