Electrical Configuration:
One sensing and one compensating element are connected to built-in FET in source follower
circuit, connections "Drain-Source-Ground". It is recommended to use a load resistor of 47k.
Electrical data:
Unless specified differently, all data refer to 25 C:
Responsivity: min.: 2,2 kV/W typ.: 3,5 kV/W Responsivity is measured within spectral range 7 - 14 m as per fig. 3 at 1Hz.
Temperature coefficient of responsivity typ.: -0.1 %/K.
Noise: max.: 50 V pp
typ.: 15 V pp
After a 10 minute settling time, noise is monitored for the duration of 1500 sec. at a temperature of 25 C, shut from infrared energy, electrical bandwidth of 0.4 to 10Hz.
Configuration:
Housing: TO- 5 metal housing with infrared transparent window
Element size: 1.5 x 1.5 mm2 see also drawing: 2/37448
Connections: Refer to drawing: 2/37448
Operating temperature: -40 C to +85 C
Storage temperature: -40 C to +85 C
Microphonic noise: max: 30uV rms/g
Humidity:
The IR-detector shall not increase noise or decrease responsivity when exposed to 95% r.H. at 30 C. Operation below dew point might effect performance.