主要功能和性能参数
1、主要功能
l 上电前合闸条件检测:输入过欠压、漏电、短路,任一故障存在不合闸;
l 运行检测保护:输入过欠压、.输出过流/短路、漏电,任一故障出现将跳闸,实施保护;.输出过流/短路、漏电保护阈值现场可设置;
l 任一项保护跳闸后,间隔30~60S后自动重合闸,重合闸前要进行合闸条件检测,符合合闸条件时才合闸,否则不合闸。
l 采用变压器隔离供电,自身的工作电源采用抗雷击能力较强的线性电源,以及大容量的压敏器件,提高整机抗雷击能力;
l 具有雷击能量检测,强雷击时跳闸,断开线路与设备连结,实现设备防雷;
l 具有实时电压、电流显示,以及累计故障和分类故障次数显示;
l 可以提供干节点告警信号;
2、 主要技术参数
l 额定电压:220V
50Hz
l 工作电压范围:120V-280V
47HZ-63HZ
l 额定输出电流:In≥6A/10A,可按客户要求定做
l 漏电保护动作电流:现场可设置
l 1档:30 mA
2档:50mA
l 漏电保护动作时间:≤100MS
l 过压保护电压
l 280V±10V,动作时间:2-5S
l 欠压保护电压
l 120V±5V,动作时间:2-5S
l 过流保护电流:现场可设置
1档:
6.5A±0.5A,动作时间:2-5S
2档:11A±1A,动作时间:2-5S
l 短路保护电流:≥3In
动作时间::≤100MS
l 实时电压、电流显示误差:≤5%
l 故障累计和分类故障次数显示:不小于10000次