*概述
LXK—Φ80~Φ240系列零序电流互感器适用于10kV及以下交流50Hz线路中作电力系统以及高压三相交电流发电机、电动机的零序过电流保护用,只适合用于户内。输电电缆外径不大于Φ80~Φ240。
零序电流互感器为电缆式,故只考核二次线圈的绝缘性能。二次线圈对地能承受3kV工频耐压。
The zero current transformers ofLXK—Φ80~Φ240 seriesis used for overdriven current protection in the electric non-useful-ground neutral system of rated frequency 50Hz or rated voltage 10kV and three phase AC dynamotor/electromotor. It is only used indoor. Electricity transmitting cable outside diameter should beΦ80~Φ240.
This zero current transformer is cable type, so we only assess the winding insulation perfoemance. The secondary winding is able to withstand the power frequency test voltage of 3 kV to ground.
*结构简介
本型互感器分为两半,用树脂浇注成半圆形,然后用夹紧连接。安装时可将互感器分为两半,然后合并为一体,安装极为方便。
The zero current transformers ofLXK—Φ80~Φ240 series are casting into two half circles. In installation, the transformer can be clipped together.
*技术参数
1、额定电流比、准确级、额定输出见表1;(Rated current ratio, accuracy class, rated output see form 1)
2、与继电器配套使用时,本型互感器一次零序电流满足表2的要求;(when used with relays, this series of transformers should satisfy the requirements of form 2)
表1
额定电流比 Rated current ratio(A) | 准确级 Accuracy class | 额定输出 Rated output(VA) |
60-75/1 | 10P10 | 1 |
100/1 | 1.5 |
150/1 | 2.5 |
200/1 | 3.75 |
300/1~600/1 | 5 |
150—200/5 | 2.5 |
300-400/5 | 5 |
500/5 | 7.5 |
600/5 | 10 |
表2
继电器型号 Relay type | 继电器线圈连接方式 Connecting method of relay windings | 继电器刻度值 Scale of relay | 一次零序电流 Primary zero sequence current(A) | 额定电流比 Rated current ratio |
DD—11/60 | 串联 Series connection | 15×1~30×1 | 2~5 | 60/1 |
并联 Parallel connection | 15×2~30×2 |
DD—11/60 | 串联 Series connection | 15×1~30×1 | 2~6 |
并联 Parallel connection | 15×2~30×2 |