1.电压
浮充电压:20℃条件下 13.38—13.80V/unit,温度调节系数为-18mV/℃/unit
Float charging voltage: below 20℃, 13.38—13.80V/unit, the temperature adjustment coefficientis-18mV/℃/unit
均充电压:14.28—14.52V/unit
Average charging voltage: 14.28—14.52V/unit
最大充电电流:0.20C10A。
Max. charging current: 0.20C10A
2.产品基本参数Basic Parameters
产品基本参数Basic Parameters | 额定 电压 V Rated voltage | 额定容量 Ah(C10) Rated capacity Ah(C10) | 长 L | 宽 W | 槽高 Slot height | 总高 Total heigh | 电池 质量 ±2%Kg Batteryweight ±2%Kg | 输出结构尺寸 Output structure size |
12 | 75AH | 350 | 170 | 180 | 180 | 21 | ||
|
3.电池主要电性能参数Main electric performance parameters
电池主要电性能参数Main electric performance parameters
| 放电时间Discharge time | ||||||||
10' | 30' | 1h | 3h | 5h | 8h | 10h | 20h |
| |
95.4 | 52.5 | 36.9 | 16.8 | 11.3 | 7.6 | 6.5 | 3.3 |
|
4.长时放电容量(Ah)Long time discharging capacity (Ah)
型号 Type | C24 | C48 | C120 | C240 | ||
Uf=10.8V | Uf=11.1V | |||||
75AH | 76 | 80 | 85 | 90 | ||
5.充电特性曲线Charge Characteristic Curve
6.不同放电率放电特性曲线Discharge Characteristic Curves at different Rate
7.放电容量与环境温度关系曲线Discharge Capacity VS Ambient Temperature Curve
8. 充电电压与环境温度关系曲线Charge Voltage VS Ambient Temperature Curve
9.安装说明;
电池安装:
1.一般情况下电池串联使用,若电池必须并联使用,并联不宜超过二路。
2.电池安装时其间距大于3cm,且避光、热、通风良好。
3.安装前去除一切个人金属物件(手机、项链等)。
4.应使用绝缘工具,绝缘手套。
5.电池上不可放置金属工具及硬物件。
6.注意电池极性,谨防反接。
充电方式:
1.浮充使用的充电方式:一般采用恒压限流,具体数值:25摄氏度时。NP型2025~2030V/单体;GM型2.23~2.25V/只;NM型2.36~2.40V/只。点了显得在0.2A(C:表示电池的额定容量)以下。当温度高于或低于25摄氏度时,浮充电压应校正,校正系数为-3mv/摄氏度 单体。
2.循环使用的充电方式:采用恒压限流方式,电流限定在0.2CA以下,25摄氏度时恒压值;NP型2.4V/单体,GM型2.35V/单体。当温度高于或低于25摄氏度时充电电压值应校正,校正系数为-4mv/摄氏度 单体。
3.均衡充电:
均衡充电采用先横流,后按NP型2.4V/单体,GM型2.35V/单体恒压充电,充电时间取决于放电深度。
(注;在浮充运动中,当一组电池中出现了个别电池的浮充电压低于2.2V/CELL方需均衡充电。)
4.补充充电:
蓄电池在运输和储存过程因自放电将损失一部分容量,若储存的时间过长,在投放使用前进行补充电。如果存储的时间在6个月~1年在恒压2.25V/单体条件下充电3天。
如果储存的时间为1~2年,在恒压2.30V/单体的条件下充电3天。
注意事项:
电池在过充时可能益处含氢的爆炸性气体,应远离火源。
1.电池因摔破等原因,使电池内酸液溅到皮肤、衣服上时,立即用大量自来水冲洗。
2.不可用任何有机溶剂清洁电池。
3.每2个月巡检一次电池,如发现落后电池应及时均衡充电仍落后,须更换同种型号新电池,如发现个别电池温度过高(高于5~10摄氏度),应立即更换新电池。
4.废电池应回收利用,不得随地弃置。
Batteries installed:
1. Usually used, if battery series, parallel to the battery must be more than two parallel unfavorable use.
2. The battery when installation, and their distance than 3cm avoid light, heat, well ventilated.
3. Before installation, remove all personal metal objects (mobile phones, necklace, etc.).
Charging ways:
1. The use of floating filling charging ways: generally USES the constant pressure the current limit and concrete numerical: 25 degrees centigrade. NP 2030V/monomer 2025 to ~ type; GM type 2.23 ~ 225 V/only; NM type 2.40 V/only 2.36 ~. O 'clock appear in 0.2 A (C: indicates that the battery rated capacity) below. When the temperature above or below 25 degrees centigrade, float charging pressure should correction, calibration coefficient for - 3mv/degrees Celsius monomer.
2. Recycle charging ways: the constant pressure the current limit way, current confined, 25 degrees below 0.2 CA when constant pressure value; NP type 2.4 V/monomer, GM type 2.35 V/monomer. When the temperature above or below 25 degrees centigrade recharging voltage value should correction, calibration coefficient for - 4mv/degrees Celsius monomer.
3. Balance charge:
Balanced by first after charging by NP, cross type 2.4 V/monomer, GM type 2.35 V/monomer constant pressure charging, charging time depends on the discharge depth.
(note: in float filling movement, when a group of battery in appeared inpidual battery charging down to float 2.2 V/CELL must balance charge.) party
4. Supplementary charge:
Batteryin transporting and storing process for self-discharge will lose part of capacity, if stored in a long time, before delivery use complement electricity. If the storage time in six months to one year in constant pressure 225 V/monomer conditions charging for three days.
Note:
The battery in the overcharge -included hydrogen may benefit the explosive gas, should be away from fire.
1. The battery for breaking wait for a reason, make a battery inside acid splashed skin and clothes, and rinse immediately with plenty of water.
2. Do not use any organic solvent cleaner batteries.
3. Once every 2 months inspection, such as the discovery of backward battery charging battery should be balanced, lags behind in new battery same model must be replaced, such as the discovery of inpidual cells to high temperature (above 5 ~ 10 degrees Celsius), should be replaced immediately new battery.
4. Waste recycling, not battery should be abandoned anywhere.
11.24系列,48系列:
24 series, 48 series
24系列是用二只12V系列蓄电池串联
24 series is to use two 12V series accumulator series
48系列是用三只12V系列蓄电池串联
48 series is to use three 12V series accumulator series