1.0 INPUT
1.1 Voltage
|
Minimum |
Normal |
Maximum |
Unit |
|
100 |
115/230 |
240 |
Vrms |
1.2 Frequency
47Hz~63Hz
1.3 Current
2A.(MAX)
1.4
Inrush current
115V/40A(max.), 230V/80A(max.)
at 25℃ at cold start.
1.5 Power efficiency
80% (min.) at full load, 110Vac or 230Vac 50Hz.
2.0 OUTPUT
2.1
Charge curve
|
Charger current(mA) |
|
Voltage(V) |
CV CC
|
4000 |
|
|
|
T |
|
16.8V |
|
6V min |
current
Voltage
2.1.1 Its output voltage is 16.8+/-1%V at standby.
2.2 Led display
Green on standby
Red on charging
Green on full charge when charging current drop to 400+/-15mA.
3.0 PROTECTION

3.1
Over voltage protection
Output over voltage protection with zener diode.
3.2 Short circuit protection
The output short to ground, it will auto-recovery without damage.
3.3 Output reverse input protectionWhen output reverse input,the unit and the battery will be no damage.

4.0 HI-POT
4.1 HI-POT
4.1.1 P~S:3300Vac 2S,the leakage current will be lower than 10mA.

5.0 ENVIRONMENT:
5.1 Ambient operation temperature
0℃ to +40℃
5.2 Ambient operation relative humidity
20% to 85%
5.3 Ambient storage temperature
-40℃ to +70℃
5.4 Ambient storage relative humidity
10% to 95%

6.0 SAFETY:
6.1 UL1310
6.2 CE
6.2.1 EN60335-2-29
6.2.2 EN60335-1
7.0 EMC:
7.1 FCC part15
7.2 EN55022 classB
7.3 EN55014-1/2
7.4 EN50366
7.5 EN61000-3-2
7.6 EN61000-3-3


8.0 DROP TEST
8.1 Freely drop the wooden board from the height of75cm
for two times per side(front/back/left/right).
9.0 VIBRATION TEST9.1 Vibration frequency:5-60-5Hz with 10 octave/min@2.1G
9.2 Three circles per axis(X,Y,Z) for 10minutes
10.0 MTBF30,000 hours base on bellcore TR332 document required at25℃.
11.0 Outline
11.1.Outline dimension: 135.5L X 65.5W X 37(H) mm MAX;