Features & BenefitsBandwidths up to 100 MHzUp to 5,600 V Differential (DC + pk AC)Up to 2,300 V Common (RMS)Overrange IndicatorSafety CertifiedSwitchable AttenuationSwitchable Bandwidth LimitApplicationsFloating MeasurementsSwitching Power Supply DesignMotor Drive DesignElectronic Ballast DesignCRT Display DesignPower Converter Design and ServicePower Device Evaluation The P5205A is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V differential probe can safely measure voltages in IGBT circuits such as motor drives or power converters. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBE? interface. The P5202A is similar to the P5205A, but this probe has approximately half the attenuation and half the dynamic range of the P5205A and better signal-to-noise ratio. CharacteristicP5200AP5202AP5205AP5210AAttenuation50X / 500X20X / 200X50X / 500X100X / 1000XDifferential Input Voltage500X: ±1300 V200X: ±640 V500X: ±1300 V1000X: ±5600 V50X: ±130 V20X: ±64 V50X: ±130 V100X: ±560 VCommon Mode Voltage500X: ±1300 V200X: ±640 V500X: ±1300 V1000X: ±5600 V50X: ±130 V20X: ±64 V50X: ±130 V100X: ±560 VMaximum Rated Input Voltage (each side rated to ground)1000 V CAT II450 V1000 V CAT II2300 V350 V CAT II1000 V CAT IIIBandwidth50 MHz100 MHz100 MHz50 MHzDifferential Input Impedance10 M?, 2 pF5 M?, 2 pF10 M?, 2 pF40 M?,
2.5 pFInput Impedance between each Input and Ground5 M?, 4 pF2.5 M?, 4 pF5 M?, 4 pF20 M?, 5 pFCable Length1.8 mTypical CMRRDC: >80 dBDC: >80 dB100 kHz: >60 dB100 kHz: >60 dB3.2 MHz: >30 dB3.2 MHz: >40 dB50 MHz: >26 dB50 MHz: >30 dBP5205AActive Differential Probe.Includes: 2 hook clips, 2 alligator clips, 2 pincer clips, 2 extension cables.保修一年!(非人为损坏)