Model |
InfraCal Model HATR-T2 |
InfraCal Model CVH |
InfraCal 2 Model ATR-SP |
InfraCal 2 Mode TRANS-SP |
Technology |
3.4μm fixed filter infrared analyzer | |||
Min detection Water |
8 ppm |
2 ppm |
0.3 ppm |
0.1 ppm |
Min detection Soil |
40 ppm |
10 ppm |
3 ppm |
1 ppm |
Solvent |
Hexane, Pentane, Cyclohexane, Vertrel MCA |
Perchloroethylene, S-316, Freon-113 |
Hexane, Pentane, Cyclohexane, Vertrel MCA |
Perchloroethylene, S-316, Freon-113 |
Components measured |
Hydrocarbons with boiling point higher than solvent |
All hydrocarbons |
Hydrocarbons with boiling point higher than solvent |
All hydrocarbons |
Method complies |
N.A. |
ASTM D7066, EPA 413.2, EPA 418.1 |
N.A. |
ASTM D7066,
EPA 413.2, EPA 418.1 |
Method compares |
EPA 1664, ISO 9377-2 |
EPA 1664, ISO 9377-2 |
EPA 1664, ISO 9377-2 |
EPA 1664,
ISO 9377-2 |
Volatile componets |
Loses |
Includes |
Loses |
Includes |
Data acquisition |
Printer from Wilks |
Printer from Wilks |
Internal data storage & export |
Internal data storage & export |
Calibrations |
Single |
Single |
Multiple |
Multiple |
Display |
4 character LED |
4 character LED |
Touch screen |
Touch screen |
Password protection |
No |
No |
Yes |
Yes |
Battery pack |
External |
External |
Internal |
Internal |
Others |
Solvents lighter than water, sample collected form container top |
Solvents heavier than water, requires separatory funnel or septa cap vial |
Solvents lighter than water, sample collected form container top |
Solvents heavier
than water,
requires
separatory
funnel or
septa cap vial |
Model |
P/N |
Description |
Min Detection 8 ppm |
405-1009 |
Includes 100 mrcroliter sypringe, Un-calibrated |
InfraCal Model HATR-T2 |
405-1009-44 |
Factory calibrated using 403-1044 |
403-1044 |
TOG/TPH calibration standard set | |
405-1009-72 |
Factory calibrated using 403-1072 | |
403-1072 |
FOG/TOG calibration standard set | |
403-1067 |
InfraLog serial printer | |
403-0013 |
Carrying case | |
403-0003 |
External 12V battery pack | |
403-0002 |
12V automotive power adapter cable | |
403-0005 |
Dust cover | |
403-1011 |
Field sampling kit | |
Min Detection 2 ppm |
405-0003/12 |
Includes set of 4-10mm cuvettes, Un-calibrated |
InfraCal Model CVH |
405-0003/12-41 |
Factory calibrated using 403-1041 |
403-1041 |
S-316 TOG/TPH calibration standard set | |
405-0003/12-40 |
Factory calibrated using 403-1040 | |
403-1040 |
S-316 FOG/TOG calibration standard set | |
405-0003/12-78 405-0003/12-64 |
Factory calibrated using 403-1064 | |
403-1064 |
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration
standard set | |
403-0012 |
Set of 4-10mm quartz cuvette cells | |
403-1067 |
InfraLog serial printer | |
403-0013 |
Carrying case | |
403-0003 |
External 12V battery pack | |
403-0002 |
12V automotive power adapter cable | |
403-0005 |
Dust cover | |
403-1063 |
Field sampling kit | |
Min Detection 0.3 ppm |
405-2034 |
Includes set of 4-10mm cuvettes, Un-calibrated |
InfraCal 2 Model ATR-SP |
405-2034-81 |
Factory calibrated using 403-1081 |
403-1081 |
Hexane TOG/TPH calibration standard set (Low range) | |
405-2034-44 |
Factory calibrated using 403-1044 | |
403-1044 |
Hexane TOG/TPH calibration standard set (High range) | |
405-2034-8144 |
Factory calibrated using 403-1081 and 403-1044 | |
405-2034-72 |
Factory calibrated using 403-1072 | |
403-1072 |
Hexane FOG/TOG calibration standard set | |
403-0013 |
Carrying case | |
403-1011 |
Field sampling kit | |
Min Detection 0.1 ppm |
405-2035 |
Includes set of 4-10mm cuvettes, Un-calibrated |
InfraCal 2 Model TRANS-SP |
405-2035-80 |
Factory calibrated using 403-1080 |
403-1080 |
S-316 TOG/TPH calibration standard set (Low range) | |
405-2035-41 |
Factory calibrated using 403-1041 | |
403-1041 |
S-316 TOG/TPH calibration standard set (High range) | |
405-2035-8041 |
Factory calibrated using 403-1080 and 403-1041 | |
405-2035-40 |
Factory calibrated using 403-1040 | |
403-1040 |
S-316 FOG/TOG calibration standard set | |
405-2035-79 |
Factory calibrated using 403-1079 | |
403-1079 |
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration
standard set (Low range) | |
405-2035-78 |
Factory calibrated using 403-1078 | |
403-1078 |
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration
standard set (High range) | |
405-2035-7978 |
Factory calibrated using 403-1079 and 403-1078 | |
403-0012 |
Set of 4-10mm quartz cuvette cells | |
403-0013 |
Carrying case | |
403-1063 |
Field sampling kit | |
403-1083 |
Field sampling kit for sub-ppm |