50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) -------------------------------------------------------------------------------------------------------------- 10MΩ or more at 500VDC megger (between lead conductor and frame)
Noise measurement method
Measured at 1m from the air inlet
Storage Temperature -------------------------------------- Operating Temprature
-30ºC to +70ºC -------------------------------------------------------------------------------------------------------------- -10ºC to +70ºC(Non-condensing)
Lead Wire
(+): red (-): black or blue Sencer: yellow
Specifications
Model No.
Rated Voltage (V)
Operating voltage range (V)
Rated current (A)
Rated input (W)
Rated speed (min-1)
Air flow (m3/min)
Static pressure (Pa)
Noise (dB[A])
Mass (g)
109L0612F401
12
10.2to.13.8
0.09
1.08
3,200
0.44 ( 15.5 CFM)
29.4 ( 0.118 inchH2O)
24
100
Typical air flow and static pressure characteristics
Dimensions (unit:mm)
Reference dimensional diagram for installation holes (unit:mm)