DNP光源SDCV-3500透射测试卡的用途和特点:
DNP Standard color Viewer
The DNP Standard color Viewer is a light source which enables youto evaluate and adjust video and still cameras. With itshigh-frequency Fluorescent lighting method, it handles imageswithout flicker.
Specification
Light source: DNP Standard color Viewer lamp
(Four 10W dedicated fluorescent tubes are used)
Power supply: AC100V 50, 60Hz
Lighting method: High Frequency lighting method 20KHz
Color rendering: Over 90% rendering evaluation-point for eachcolor
Color temperature: (Measured by Minolta CL-200)
Operating temperature: 10~40℃
Operating humidity: Below 80%(avoid dew)
Major diameter dimension: 375W×365H×165D m/m
Luminance plane dimension: 250W×190H m/m
Color chart dimension: 320W×290H m/m
Power consumption: 80W
Weight: 6.5kg/7.5kg
CCV-31F
CCV-51F
CCV-31F/G
CCV-51F/G
●The Luminance plane characteristics: according to the types ofself-contained fluorescent lamp
Product Type Luminance Color Temperature Lamp Color TemperatureLuminance Color matching shift Weight
CCV-31F Fixed FL10WW-DLB 3100K±300 Over 1300cd/m2 Within 10%6.5kg
CCV-51F Fixed FL10D-EDL-56K 5100K±300 Over 1400cd/m2 Within 10%6.5kg
CCV-31F/G Volume adjustable FL-10WW-DLB 3100K±300 Over850~1300cd/m2 Within 10% 7.5kg
CCV-51F/G Volume adjustable FL10D-EDL-56K 5100K±300 Over850~1400cd/m2 Within 10% 7.5kg
*The color temperature if Luminance. Color Temperature ConversionType viewer ranges over 50k according to the change of theLuminance.
*The specification may change without notice
Operation Manual
【1】 Before using the product:
Power supply AC 100V, 50/60Hz shared
Light source 10W DNP Standard color Viewer Lamp(4)
Power consumption 80W

【2】 Using the DNP Standard color Viewer
(1) Plug the power cable of the product intoAC100V
【Precautions】 Do not connect any power supply otherthan AC100V
If the other power supply connected by accident, the inverterinside will burned out
(2) Turn on the power switch
(3) Lamp lights: the lamp light will stabilised after 15 to20 minutes at the room temperature(20℃)
(4) If the lamp does not lit, call for Service Office forthe confirmation as described on other documents.
(5) To suspend snaking of the lamp, press power switch 3 to4 times [as ON/OFF].
【3】 If the light does not lit
Call for Service Office to confirm thefollowing:
(1) AC 100V supplied to the wall socket.
(2) Plug the product into the wall socket.
(3) Turn the power supply switch of the productON
Still the lamp does not lit: Consider thefollowing:
(1) Two of the viewer lamps lit simultaneously, one of thefuses of the inverters has blowouts.
(2) Four of the viewer lamps does not light means that eachof the fuses of the two inverters has blowouts.
【Precautions】 The above occurs if the applied powersupply is not AC 100V.
Fuse bum out cause internal burnout of inverter. The burnedinverter needs to replace.
【4】 How to replace the lamp and keep it clean
Place the Viewer on the flat table, and plug out the powersupply cable from the wall socket.
Remove the used device in the following order:
(1) Unfasten the two of grub screws on the topframe.
(2) To remove the top frame from the main unit;
Holding 50 to 60 mm the grub screw of the top frame and press itforward.
(3) Remove the glass plate and acrylic plate.
【Precaution】 Glass plate easily breaks and may hurtyour hands and fingers.
Handle the edge of the plate with care not to scratch.
◆Replacing the lamps:
(1) When the lamps used over 2,000 hours or one year, itneeds to replace.
(2) Remove the Lamp Tubes: Hold the edge of the Lamp Tubes,and turn it 90 degree.
◆Cleaning the device:
(1) Impregnate alcohol to gauze then apply it onto thesurface of the reflection plate / acrylic plate / glass surface toremove the dirt.
(2) Clean the device once in six months to one year to keepquality of the Color Temperature and Luminance.
【5】 Other Precautions
Handling the viewer needs the following precautions becauseit contains the parts using glass.
(1) Do not add strong impact on the viewer
(2) Do not put any heavy items on the surface of theviewer
DNP Standard color Viewer | |
|
|
|
The DNP Standard color Vieweris a light source which enables you to evaluate and adjust videoand still cameras. With its high-frequency Fluorescent lightingmethod, it handles images without flicker. |
|
Lightsource: | DNP Standard color Viewerlamp (Four 10W dedicated fluorescent tubes are used) | Powersupply: | AC100V 50, 60Hz | Lightingmethod: | High Frequency lightingmethod 20KHz | Colorrendering: | Over 90% renderingevaluation-point for each color | Colortemperature: | (Measured by MinoltaCL-200) | Operatingtemperature: | 10~40℃ | Operatinghumidity: | Below 80%(avoiddew) | Major diameterdimension: | 375W×365H×165Dm/m | Luminance planedimension: | 250W×190H m/m | Color chartdimension: | 320W×290H m/m | Powerconsumption: | 80W | Weight: | 6.5kg/7.5kg |
| | | CCV-31F CCV-51F | | | CCV-31F/G CCV-51F/G | |
|
|
●The Luminance planecharacteristics: according to the types of self-containedfluorescent lamp |
ProductType | LuminanceColor Temperature | Lamp | ColorTemperature | Luminance | Colormatching shift | Weight | CCV-31F | Fixed | FL10WW-DLB | 3100K±300 | Over1300cd/m2 | Within10% | 6.5kg | CCV-51F | Fixed | FL10D-EDL-56K | 5100K±300 | Over1400cd/m2 | Within10% | 6.5kg | CCV-31F/G | Volumeadjustable | FL-10WW-DLB | 3100K±300 | Over850~1300cd/m2 | Within10% | 7.5kg | CCV-51F/G | Volumeadjustable | FL10D-EDL-56K | 5100K±300 | Over850~1400cd/m2 | Within10% | 7.5kg |
|
*The color temperature ifLuminance. Color Temperature Conversion Type viewer ranges over 50kaccording to the change of the Luminance. *The specification may change without notice |
|
【1】 | Before using theproduct: | | | Power supply | | AC 100V, 50/60Hzshared | Light source | | 10W DNP Standard color ViewerLamp (4) | Power consumption | | 80W |
|
【2】 | Using the DNPStandard color Viewer | | | (1) | Plug the power cable of theproduct into AC100V | | | 【Precautions】 | Do not connect any powersupply other than AC100V If the other power supply connected by accident, the inverterinside will burned out |
| | (2) | Turn on the powerswitch | | (3) | Lamp lights: the lamp lightwill stabilised after 15 to 20 minutes at the roomtemperature(20℃) | | (4) | If the lamp does not lit,call for Service Office for the confirmation as described on otherdocuments. | | (5) | To suspend snaking of thelamp, press power switch 3 to 4 times [as ON/OFF]. |
|
【3】 | If the light doesnot lit | | | Call for ServiceOffice to confirm the following: | | (1) | AC 100V supplied to the wallsocket. | | (2) | Plug the product into thewall socket. | | (3) | Turn the power supply switchof the product ON | | | | | | | Still the lampdoes not lit: Consider the following: | | | | | | | (1) | Two of the viewer lamps litsimultaneously, one of the fuses of the inverters hasblowouts. | | (2) | Four of the viewer lamps doesnot light means that each of the fuses of the two inverters hasblowouts. | | | 【Precautions】 | The above occurs if theapplied power supply is not AC 100V. Fuse bum out cause internal burnout of inverter. The burnedinverter needs to replace. |
|
|
【4】 | How to replacethe lamp and keep it clean | | | Place the Vieweron the flat table, and plug out the power supply cable from thewall socket. Remove the used device in the following order: | | (1) | Unfasten the two of grubscrews on the top frame. | | (2) | To remove the top frame fromthe main unit; Holding 50 to 60 mm the grub screw of the top frame and press itforward. | | (3) | Remove the glass plate andacrylic plate. | | | 【Precaution】 | Glass plate easily breaks andmay hurt your hands and fingers. Handle the edge of the plate with care not to scratch. |
| | | ◆Replacing thelamps: | | (1) | When the lamps used over2,000 hours or one year, it needs to replace. | | (2) | Remove the Lamp Tubes: Holdthe edge of the Lamp Tubes, and turn it 90 degree. | | | ◆Cleaning thedevice: | | (1) | Impregnate alcohol to gauzethen apply it onto the surface of the reflection plate / acrylicplate / glass surface to remove the dirt. | | (2) | Clean the device once in sixmonths to one year to keep quality of the Color Temperature andLuminance. |
|
【5】 | OtherPrecautions | | | Handling theviewer needs the following precautions because it contains theparts using glass. | | (1) | Do not add strong impact onthe viewer | | (2) | Do not put any heavy items onthe surface of the viewer |
|