S3000专业CMS介绍
S3000专业CMS成功的将人员的保护和周围的环境轮廓的测量融为一体。该系统开辟了一条物流行业实现安全防护与效率完美结合的新途径。
系统组成与特点
* 人员防护与周围轮廓检测于一体 * 测量数据通过RS422通信接口时传输
* 反射镜的最大检测距离达30米 * 可实现实践控制的数据输出
* 可设置最多8个保护/警告区域 * 静态/动态保护选择开关
* 具备S3000专业型的全部功能 * 模块化设计
* 保护区域半径4m,5.5m,7m * 参数存储
* 分辨率可设置 * 经过认证可以垂直向下安装
* 7段码显示 * EDM外部触点监控
* 总线接
典型应用
Safety Laser Scanners | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
Applications | |||
![]() | Hazardous area protection (vertical): | ![]() | ![]() |
![]() | ess protection (vertical): | ![]() | ![]() |
![]() | Hazardous area protection (horizontal): | ![]() | ![]() |
![]() | ![]() |
Functions | |||
![]() | Static control outputs for switching between warning fields: | ![]() | ![]() |
![]() | Incremental encoder inputs: | ![]() | ![]() |
![]() | External device monitoring: | ![]() | ![]() |
![]() | Integrated configuration memory: | ![]() | ![]() |
![]() | Reflector mark detection: | ![]() | ![]() |
![]() | Expanded measured data output: | ![]() | ![]() |
![]() | Safe device communication via EFI/SDL: | ![]() | ![]() |
![]() | ![]() |
Technical data | |||
![]() | Laser protection class: | 1 (21 CFR 1040.10 und 1040.11, IEC 60825-1:2001) | ![]() |
![]() | Enclosure rating: | IP 65 (EN 60529) | ![]() |
![]() | Protection class: | II (DIN VDE 0160, DIN EN 50178) | ![]() |
![]() | Type: | Type 3 (IEC/EN 61496-3) | ![]() |
![]() | Safety integrity level: | SIL2 (IEC 61508), SILCL2 (EN 62061) | ![]() |
![]() | Category: | category 3 (EN ISO 13849) | ![]() |
![]() | Performance Level: | PL d (EN ISO 13849) | ![]() |
![]() | PFHd: | 5,29 * 1E-08 | ![]() |
![]() | TM (Mission Time): | 20 a | ![]() |
![]() | Ambient operating temperature from ... to: | -10 °C ... 50 °C | ![]() |
![]() | Dimensions (W x H x D): | 102 mm x 152 mm x 105 mm | ![]() |
![]() | Weight: | 1.2 kg | ![]() |
![]() | Scan angle: | 270 ° | ![]() |
![]() | Protective field range: | 2 m | ![]() |
![]() | Maximum warning field range: | 8 m | ![]() |
![]() | Number of field sets: | 8 | ![]() |
![]() | Response time: | 80 ms | ![]() |
![]() | Resolution: | 30 mm, 40 mm, 50 mm, 70 mm, selectable | ![]() |
![]() | Distance measuring range: | 30 m | ![]() |
![]() | Number of multiple samplings: | configurable via CDS 2 ... 16 | ![]() |
![]() | Electrical connection: | Plug-in connection housing with screw, Screw-type terminals | ![]() |
![]() | Supply voltage: | 16.8 V DC, 24 V DC, 30 V DC | ![]() |
![]() | Number of EDM inputs: | 1 | ![]() |
![]() | Number of reset-/restart inputs: | 1 | ![]() |
![]() | Number of static or dynamic control inputs: | 2 | ![]() |
![]() | Number of stand-by inputs: | 1 | ![]() |
![]() | Number of safe outputs: | 2, Safety outputs (OSSD) | ![]() |
![]() | Number of warning field outputs: | 1 | ![]() |
![]() | Number of application diagnostic outputs: | 1 | ![]() |
![]() | Maximum output current: | 250 mA | ![]() |
![]() | Configuration and diagnostics interface: | RS-232 | ![]() |
![]() | Data interface: | RS-422 |