1 |
直线槽/线条 |
![](http://i03.c.aliimg.com/img/ibank/2012/454/326/490623454_1214867394.jpg) |
标准1米长度,规格:12x8mm,上下2组并和组成,材质:PVC
|
|
2 |
光缆固定槽 |
![](http://i04.c.aliimg.com/img/ibank/2011/413/808/399808314_1214867394.jpg) |
用于线槽内蝶形引入光缆的固定 |
|
3 |
收尾线槽 |
![](http://i00.c.aliimg.com/img/ibank/2011/808/443/395344808_1214867394.jpg) |
在线槽末端处使用,起保护光缆的作用 |
|
4 |
封洞线槽 |
![](http://i05.c.aliimg.com/img/ibank/2012/725/595/490595527_1214867394.jpg) |
线槽方式敷设蝶形引入光缆时,在光缆穿越墙洞处使用 |
|
5 |
阳角、阴角、弯角 |
![](http://i04.c.aliimg.com/img/ibank/2012/559/586/529685955_1214867394.jpg) |
弯角:线槽在平面转弯处使用 阴角:线槽在内侧直角转弯处使用 阳角:线槽在外侧直角转弯处使用 |
|
6 |
波纹管管卡 |
![](http://i05.c.aliimg.com/img/ibank/2012/890/885/490588098_1214867394.jpg) |
用于波纹管的固定 |
|
7 |
卡钉扣 |
![](http://i01.c.aliimg.com/img/ibank/2012/208/006/490600802_1214867394.jpg) |
塑料夹扣,在户内采用直接敲击的钉固方式敷设蝶形引入光缆 |
|
8 |
线槽软管 |
![](http://i03.c.aliimg.com/img/ibank/2012/452/037/489730254_1214867394.jpg) |
线槽在跨越电力线或在墙面弯曲不平处使用 |
|
9 |
连接片 |
![](http://i01.c.aliimg.com/img/ibank/2012/558/316/490613855_1214867394.jpg) |
直线槽与线槽软管之间连接头 2 件/套 |
|
10 |
螺钉扣 |
![](http://i04.c.aliimg.com/img/ibank/2011/242/054/456450242_1214867394.jpg) |
塑料夹扣,在户外采用螺丝钉 固方式敷设自承式蝶形引入 光缆。 |
|
11 |
过墙套管 |
![](http://i04.c.aliimg.com/img/ibank/2012/425/907/529709524_1214867394.jpg) |
蝶形引入光缆在户内洞口处穿越墙洞时的美观与保护材料
孔径:10mm |
|
12 |
紧箍钢带/抱箍 |
![](http://i05.c.aliimg.com/img/ibank/2012/943/506/490605349_1214867394.jpg) |
直径130-240mm |
|
13 |
S 型固定件/光缆 钢丝紧张器 |
![](http://i01.c.aliimg.com/img/ibank/2012/855/485/490584558_1214867394.jpg) |
用于绑扎自承式引入光缆吊线,并将光缆拉挂在支撑器件上 |
|
14 |
紧箍拉钩 |
![](http://i01.c.aliimg.com/img/ibank/2012/245/106/490601542_1214867394.jpg) |
采用紧箍铜带安装在电杆上,用于将S 固定件连接固定的器件 |
|
15 |
C 型拉钩 |
![](http://i03.c.aliimg.com/img/ibank/2012/993/948/494849399_1214867394.jpg) |
采用螺丝安装在建筑物的外墙,用于将S 固定件连接固定 |
|
16 |
理线钢圈 |
![](http://i05.c.aliimg.com/img/ibank/2012/362/906/490609263_1214867394.jpg) |
用于电杆上蝶形引入光缆的垂直走线 |
|
17 |
夹板拉钩 |
![](http://i01.c.aliimg.com/img/ibank/2012/184/995/490599481_1214867394.jpg) |
紧固在钢绞线上,用于将S 固定件连接固定在钢绞线上的器件 |
|
18 |
抱箍拉钩 |
![](http://i01.c.aliimg.com/img/ibank/2012/355/195/490591553_1214867394.jpg) |
采用螺丝紧箍安装在电杆上,用于将S 固定件连接固定的器件 |
|
19 |
120型光纤门头盒 |
![](http://i03.c.aliimg.com/img/ibank/2012/875/696/489696578_1214867394.jpg) |
120*90*24mm |
|
20 |
光纤预留盒 |
![](http://i05.c.aliimg.com/img/ibank/2012/629/095/490590926_1214867394.jpg) |
用于入户前的光缆预留(可盘15-20M)0.08KG 100*100*45mm |
|
21 |
热熔管(1.0*5.0*60mm)
皮线光缆保护盒
螺钉锥(环行拉钩) |
![](http://i05.c.aliimg.com/img/ibank/2012/520/770/533077025_1214867394.jpg)
![](http://i05.c.aliimg.com/img/ibank/2012/567/172/627271765_1214867394.jpg)
![](http://i05.c.aliimg.com/img/ibank/2012/659/170/689071956_1214867394.jpg)
![](http://i01.c.aliimg.com/img/ibank/2012/469/170/689071964_1214867394.jpg)
![](http://i01.c.aliimg.com/img/ibank/2011/559/630/462036955_1214867394.jpg)
|
FTTH 专用,可与日新机配套使用 |
|
22 |
多功能86 型一光 二电光纤桌面盒 |
![](http://i05.c.aliimg.com/img/ibank/2012/599/360/533063995_1214867394.jpg) |
可与SC适配器和康普模块配套使用 |
|
23 |
多功能86 型一电 二光光纤桌面盒 |
![](http://i05.c.aliimg.com/img/ibank/2012/504/570/533075405_1214867394.jpg) |
可与2个SC适配器和一个安普模块配套使用 |
|
24 |
86 型2 口光纤桌 面盒 |
![](http://i02.c.aliimg.com/img/ibank/2012/595/468/488864595_1214867394.jpg)
![](http://i01.c.aliimg.com/img/ibank/2012/811/502/519205118_1214867394.jpg)
|
可放FC或SC或ST适配器等 |
|
25 |
四通盒 |
![](http://i03.c.aliimg.com/img/ibank/2012/605/583/489385506_1214867394.jpg) |
120*120*60mm (大孔:45mm 小孔:25mm) |
|
26 |
过路盒 |
![](http://i01.c.aliimg.com/img/ibank/2012/843/780/533087348_1214867394.jpg) |
120*120*60mm (6 通25mm) |
|
27 |
4口光纤桌面盒 |
![](http://i03.c.aliimg.com/img/ibank/2012/531/293/489392135_1214867394.jpg) |
150*110*30mm |