OFM2000 (OPTICAL FLOW METER) 插入式激光流量计
一、技术特点(Features):
1.1测量不受气体组份变化影响
1.2插入式安装,维护简单
1.3宽量程比:1500:1
1.4无压力损失,无零点漂移
1.5适合恶劣测量环境
1.6震动不会影响测量
二、技术指标
2.1测量原理:激光法
2.2测量范围(流速)[Velocity Measurement Range]:0.1m/s -150m/s
2.3重复性[Repeatability]: +/-1%
2.4精确度[Measurement uracy]: +/- 5% (0.1 m/s to 1 m/s)
+/- 2.5% (1 m/s to 100 m/s)
+/- 5% (100 m/s to 150 m/s)
2.5 过程温度范围[Process Temperature]: -40 to +100 ºC
2.6 过程压力范围[Maximum Process Pressure]: 20bar g
2.7 适合管道尺寸[Pipe Diameter]: 100mm to 800mm
2.8 环境温度[Ambient Temperature]: -20 to +50 ºC
2.9 供电[Power Requirements]: 10 - 30 VDC
2.10 信号输入[Analog Input Interface]: Pressure and Temperature Transmitter (4 - 20 mA)
2.11 信号输出[ Output Signa]: Frequency/Pulse(频率/脉冲),4-20mA,RS232,RS485(MODBUS)
Alarm(开关报警)
2.12 探头直径[Probe Diameter ]: 19.1mm (0.75")
2.13 标准探头长度[Probe Length]: 525 mm (20.7")
2.14 探头本体材料[Wetted Materials Meter Body]: 316LSS
2.15 光学窗口[Optical Windows]:硼硅酸盐玻璃( Borosilicate Glass)
2.16 连接线缆[Fiber-Optic Extension Cable]: 3/8"可拆卸柔性铠装电缆
(3/8 in detachable flexible armoured cable)
2.17 防护等级[Electronics Enclosures]: NEMA 4X (Class 1 Zone 2)
2.18 防爆等级[Explosion-proof ]: EExdIICT4
三、应用领域
3.1 烟道气
3.2 火炬气
3.3 一次混合风(电厂)
3.4 二次助燃风(电厂)
3.5 焚烧炉气
3.6 废气、燃烧气等