Application be applied to either a hot or a cold mold (ambient to370°F /188°C). For best results, thePM-50Ashould be cured on the mold at200°F /93°Cor the molding temperature (whichever is higher) to achieve the maximum number of releases per application.
1. Thoroughly clean the mold with Chem-Trend mold cleaner to remove the previous release agent or other contamination. Wipe dry with a clean cloth or towel. Then wipe with a clean solvent or naphtha and let air dry.
2. Hold spray tip 4-10"/10-25 cmfrom surface and use a light, even spray.
3. To pretreat or condition the clean mold, applyPM-50Ain a well-ventilated area. Apply at least three, uniform, thin coats and allow 5-10 minutes between applications for air drying of each coat. A short baking of the conditioned mold (10-15 minutes) at200°F /93°Cor the molding temperature (whichever is higher) will improve the durability of thePM-50Afilm and will provide the maximum number of releases per application. Begin molding.
4. Reapply a light coat of thePM-50Awhen required, to maintain desired release. To prevent buildup, avoid over-application.
Storage
Do not store at temperatures above100°F /38°C. Keep container tightly sealed to prevent evaporation and/or moisture contamination. If stored in cold temperatures, allow produPM to warm to room temperature prior to use.
HandlingWe believePM-50Ahas a low degree of hazard when used as intended. For more information, request a copy of Chem-Trend's Material Safety Data Sheet.
PackagingPM-50Ais available in 15 fl. oz.aerosol cans, 12 cans per case.