特点:
高效率,高可靠、低成本
全球适用AC输入电源
100%满负荷烧机测试
保护特性:短路/过载/过压
PWM控制和调节
内置直流电扇强迫风冷
内置风机开关控制
工作频率25KHz
一年保质期型号 | S-350-5 | S-350-7.5 | S-350-12 | S-350-13.5 | S-350-15 | S-350-24 | S-350-27 | S-350-48 |
输出 | 直流输出电压 | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
输出电压容差(注3) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
额定输出电流(注4) | 50A | 40A | 29A | 25.8A | 23.2A | 14.6A | 13A | 7.3A |
输出电流范围 | 0-50A | 0-40A | 0-29A | 0-25.8A | 0-23.2A | 0-14.6A | 0-13A | 0-7.3A |
输出功率 | 250W | 300W | 348W | 348.3W | 348W | 350.4W | 351W | 350.4W |
纹波及噪音(注2) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p |
直流电压可调范围 | -10%,+12% | ±20% | -16%,+10% | -12%,+11% | -10%,+20% | -16%,+10% | -4%,+18% | -15%,+17% |
启动、上升、保持时间 | 200ms,50ms,20ms满载 |
输入 | 输入电压范围 | 90~132 VAC/180~264VAC 47~63 Hz;由开关选择254~370VDC |
交流输入电流 | 6.5A/115 V 4A/ 230 V |
效率 | 74% | 76% | 76% | 79% | 78% | 81% | 82% | 83% |
冲击电流 | 冷启动电流50A/115V 50A/230V |
漏电流 | <3.5 mA/240VAC |
保护特性 | 过载保护 | 105%~135% |
保护方式:电流限制 ,自动恢复 |
过电压保护 | 115%~135% |
保护方式:电压限制 ,自动恢复 |
风机开/关控制 | RT3≥55℃风机开,≤45℃风机关,≥80℃切断输出 (5~7.5V) |
RT3≥65℃风机开,≤55℃风机关,≥80℃切断输出 (12~15V) |
RT3≥70℃风机开,≤60℃风机关,≥85℃切断输出 (24~48V) |
环境 | 工作温度、湿度 | -10℃~+60℃;20%~90 %RH |
保存温度、湿度 | -20℃~+85℃;10%~95 %RH |
抗震性 | 10~500Hz,2G 10min./1周期,时长60分钟,各轴 |
安全 | 耐压性 | 输入输出间:1.5KVAC 输入与地:1.5KVAC 输出与地:0.5KVAC |
绝缘电阻 | 输入输出间,输入与地,输出与地: 100M Ohms/500VDC |
符合标准 | 安全标准 | 符合UL1950 |
EMC标准 | Drsign refer to FCC Part15 J Conduction Class A |
其它 | 重量 | 1.1.5Kg |
包装 | 12pcs/14.3Kg/0.93CUFT |
备注 | - 所有参数在未特别指明时,都是在230VAC电压输入,额定负载和25℃条件下测量所得值。
- 纹波和噪声电压是在20MHz带宽示波器带12英寸双绞线末端加0.1μ和47μ电容时测得。
- 容差是电压设定误差、电压调整率和电流调整率之总和。
- 具体输出电流见输出降额曲线。
|
'