Ceraphant T PTC31 模拟转换器 智能开关
Process pressure. Pressure switch for safe measurement and monitoring of absolute and gauge pressures.
Your benefits
This compact pressure switch impresses with the latest in technology being used:
Pressure switch for monitoring absolute and gauge pressures in gases, vapours, liquids and dust.
Ceraphant T PTC31 − with ceramic sensor diaphragm.
测量原理 | Pressure switch | |
Characteristic | Intelligent pressure switch with ceramic, vacuum tight measuring cell, longterm stable and overload resistant | |
Supply / Communication | 12...30VDC | |
Accuracy | 0,5% | |
Long term stability | 0,15% of URL/year | |
Process temperature | -40°C...100°C (-40°F...212°F) | |
Ambient temperature | -40°C...85°C (-40°F...185°F) | |
Measuring range | 100mbar...40bar (1.5psi...600psi) | |
Max. overpressure limit | 60bar (900psi) | |
Process connection | Threads | |
Output | 1x PNP switch 2x PNP switch 1x PNP switch + 4...20mA analogue | |
Certificates / Approvals | CULUS EN10204-3.1 | |
Options | calibration protocol | |
Specialities | Digital display Robust SS-housing with Ra < 0,8 micron | |
Hint | Please check also temperature switch Thermophant T with the identical look and feel of the housing, electronics and software. |
Cerabar M PMC51 智能/模拟压力变送器
采用陶瓷传感器的压力变送器
具有模拟, HART, PROFIBUS PA 或FF基金会现场总线通信协议
优点
极高的可重复性和长期运行稳定性
高精度: ±0.15%,铂金级:±0.075%
量程比100:1
全模块化设计用于差压、静压和压力(Deltabar M - Deltapilot M - Cerabar M), 如: - 可更换的显示单元 - 通用的电子模块
调试简单,不需要借助其他操作工具
现场菜单引导式操作 – 通过现场显示模块 – 通过4 ... 20 mA HART – 通过PROFIBUS PA – 通过FF基金会现场总线
Cerabar M压力变送器可用于解决以下测量问题:
Characteristic | Smart and reliable pressure transmitter with capacitive measuring cell and ceramic process isolating diaphragm Ceraphire) | |
Supply / Communication | 4 ..20mA HART: 11,5...45V DC Ex ia: 11,5...30V DC PROFIBUS PA/ FOUNDATION Fieldbus: 9..32 V DC (Non Ex) | |
Accuracy | Standard 0,15% Platinum 0,075% | |
Long term stability | 0,1% of URL/year | |
Process temperature | -40°C...130°C (-40°F...266°F 150°C for 1h (302°F for 1h) | |
Ambient temperature | -40°C...85°C (-40°F...185°F) | |
Measuring range | 100mbar...40bar (1.5psi...600psi) | |
Max. overpressure limit | 60bar (900psi) | |
Process connection | Thread: G1/2...G2, R1/2, MNPT1/2 Flange: DN25...DN80, ASME 1"...4", JIS 10K | |
Hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS DRD | |
Output | 4...20 mA 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus | |
Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI SIL EN10204-3.1 NACE CoC ASME-BPE 3A, EHEDG Marine | |
Options | Display PWIS free | |
Specialities | SIL 2 according to IEC 61508 |
E+H 绝压和表压变送器 数显压力变送器 Cerabar S PMC71
Pressure transmitter with ceramic sensor
Overload-resistant and function-monitored; Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus
Your benefits
测量原理 | Hydrostatic | |||||||||||||||||||||||||||||||||||||||||||||
Characteristic / Application | Digital transmitter with capacitive sensor and ceramic membrane Modular transmitter Long term stability Enhanced safety via self diagnostic functions Secondary process barrier | |||||||||||||||||||||||||||||||||||||||||||||
Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC | |||||||||||||||||||||||||||||||||||||||||||||
Accuracy | 0,075% "PLATINUM" 0,05% | |||||||||||||||||||||||||||||||||||||||||||||
Long term stability | 0,05% of URL/year | |||||||||||||||||||||||||||||||||||||||||||||
Ambient temperature | -40°C...85°C (-40°F...185°F) | |||||||||||||||||||||||||||||||||||||||||||||
Process temperature | -40°C...150°C (-40°F...302°F) | |||||||||||||||||||||||||||||||||||||||||||||
Process pressure absolute / max. overpressure limit | 60bar (900psi) | |||||||||||||||||||||||||||||||||||||||||||||
Pressure measuring range | 100mbar...40bar (1.5psi...600psi) | |||||||||||||||||||||||||||||||||||||||||||||
Main wetted parts | Ceraphire ceramic Alloy C 316L Monel PVDF | |||||||||||||||||||||||||||||||||||||||||||||
Process connection | Threads Flanges Tri-Clamp ISO2852 Hygienic connections | |||||||||||||||||||||||||||||||||||||||||||||
Max. measurement distance | 400m (1312ft) H2O | |||||||||||||||||||||||||||||||||||||||||||||
Output | 4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus | |||||||||||||||||||||||||||||||||||||||||||||
Certificates / Approvals | ATEX FM CSA TIIS NEPSI IECEx SIL WHG/ Overfill prevention EN10204-3.1 GL marine | |||||||||||||||||||||||||||||||||||||||||||||
Options | HistoROM/M-Dat 4-line digital display SS- or Aluminiumhousing Separate housing | |||||||||||||||||||||||||||||||||||||||||||||
Specialities | diagnostic functionalities different languages in software | |||||||||||||||||||||||||||||||||||||||||||||
Application limits | Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure
|