ATC1500-S适用于电源厂OQC出货检验或生产线在线测试,可迅速自动转换成测试报表。
同时有效的排除了人们手工测试产生错误的可能性, 从而降低了客户的退货率!
系统主要优势:
ATC1500-S系统配置:
系统测试项目:
自动测试控制软件:
系统技术参数:
Test Name | Parameters Tested and Range | Accuracy |
START UP | Inrush current: 0 – 83A Startup time: 0 to 65 sec. Output voltage overshoot: 0 – 60V | ±2% (reading + range) ±1ms ±1% (reading + range) |
UVLO | Functional test only, Pass/Fail | N/A |
IDLE | Standby input power: 0 – 100W Standby input current: 0 – 10A Input voltage: 30 – 280V | ±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) |
STANDARD CV (constant current and constant resistance load) | CC Mode: 0 – 15A CR Mode: 0.1 – 50Ohm Input voltage: 30 – 280V Input Current: 0 – 10A Input Power: 0 – 200 W Power Factor 0 – 1.0 Output Voltage 0 – 60V Output Current 0 – 15A Efficiency: 0 – 100% Ripple/Noise 200kHz: 0 – 500mV Ripple/Noise 20MHz: 0 – 500mV | ±0.2% (reading + range) ±0.4% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.2% (reading + range) ±0.05% (reading + range) ±0.1% (reading + range) ±0.25% (reading + range) ±2% (reading + 5mV) ±2% (reading + 5mV) |
STANDARD CC
(constant voltage and constant resistance load) | CV Mode: 0 – 60V CR Mode: 0.1 – 50Ohm Input voltage: 30 – 280V Input Current: 0 – 10A Input Power: 0 – 200 W Power Factor 0 – 1.0 Output Voltage 0 – 60V Output Current 0 – 15A Efficiency: 0 – 100% | ±0.1% (reading + range) ±0.3% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.2% (reading + range) ±0.05% (reading + range) ±0.1% (reading + range) ±0.25% (reading + range) |
SHORT CIRCUIT
| Input voltage: 30 – 280V Input Current: 0 – 10A Input Power: 0 – 200 W Power Factor 0 – 1.0 Output Average Current: 0 – 15A | ±0.1% (reading + range) ±0.1% (reading + range) ±0.1% (reading + range) ±0.2% (reading + range) ±0.2% (reading + range)* *For steady current |
OVER CURRENT
| Current trip point: 0 – 15A Trip point voltage: 0 – 60V | ±1% (reading + range)+(step size) ±1% (reading + range) |
OVER VOLTAGE | OV trip point: 0 – 60V | ±1% (reading + range) |
LINE REGULATION | Voltage regulation: 0 – 100% | ±0.1% (reading + range) |
LOAD REGULATION | Voltage regulation: 0 – 100% | ±0.1% (reading + range) |
POWER DOWN | Holdup time: 0 – 65 sec. Input voltage: 0 – 280V Output current: 0 – 15A Output voltage overshoot: 0 – 60V | ±1ms ±0.1% (reading + range) ±0.1% (reading + range) ±1% (reading + range) |
Global Setting | Load On Voltage: 0 – 60V Wait Time: 0 – 32767 sec. Nominal Output Voltage: 0-60V Nominal Output Current: 0-15A | ±1% (reading + range) ±1ms ±1% (reading + range) ±1% (reading + range) |
Optional Setting | Bias Output Voltage : 0 – 28V Relay State rated current: 5A | ±1% (reading + range) - |
概述:
应用特性: